Procedure
After loading your recipe with Define Job, Check your recipe for the correct Blade Type, Wafer Shape (Circular or Rectangular), Wafer Diameter (circular), Y and X dimension (rectangular), Wafer Thickness, Depth and Index (the distance between cuts).
Parameters
| Wafer Thickness | Blade | Spindle Speed | Feed Rate |
|---|---|---|---|
| Up to 600 µm with a new blade | K&S G1030-Q5HH-000 (obsolete) | 27-30 KRPM | 2.5-10 mm/sec |
| Up to 600 µm with a new blade | K&S S1230-Q5HH-000 (obsolete) or SC-20-Q-D0-DE | 27-30 KRPM | 2.5-10 mm/sec |
| Up to 1100 µm with a new blade | K&S S2550-Q5HH-000 (obsolete) or SC-20-Q-D0-HH | 27-30 KRPM | 2.5-10 mm/sec |
Characterization
- Kerf Width is typically 50 µm with the K&S S1230-Q5HH-000 blade (obsolete).
- Kerf Width is typically 42 µm with the K&S G1030-Q5HH-000 blade (obsolete).
- Kerf Width is typically 36-40 µm with the K&S SC-20-Q-D0-DE blade.
- Kerf Width is typically 80 µm with the K&S S2550-Q5HH-000 blade (obsolete).
- Kerf Width is typically 61-70 µm with the K&S SC-20-Q-D0-HH blade.
- Minimal chipping.
Limitations
- The total thickness of the wafer plus all other layers may be no more than the capability of the blade.