Module:Hatnote-inline

From LNF Wiki
Jump to navigation Jump to search

Documentation for this module may be created at Module:Hatnote-inline/doc

--------------------------------------------------------------------------------
--                              Module:Hatnote-inline                         --
--                                                                            --
-- This module produces hatnote-style links and links to related articles,    --
-- but inside a <span>, instead of the <div> used by Module:Hatnote.  It      --
-- implements the {{hatnote-inline}} meta-template.                           --
--------------------------------------------------------------------------------

local libraryUtil = require('libraryUtil')
local checkType = libraryUtil.checkType
local mArguments -- lazily initialise [[Module:Arguments]]
local yesno -- lazily initialise [[Module:Yesno]]

local p = {}

--------------------------------------------------------------------------------
-- Helper functions
--------------------------------------------------------------------------------

local function getArgs(frame)
	-- Fetches the arguments from the parent frame. Whitespace is trimmed and
	-- blanks are removed.
	mArguments = require('Module:Arguments')
	return mArguments.getArgs(frame, {parentOnly = true})
end

local function removeInitialColon(s)
	-- Removes the initial colon from a string, if present.
	return s:match('^:?(.*)')
end

function p.findNamespaceId(link, removeColon)
	-- Finds the namespace id (namespace number) of a link or a pagename. This
	-- function will not work if the link is enclosed in double brackets. Colons
	-- are trimmed from the start of the link by default. To skip colon
	-- trimming, set the removeColon parameter to true.
	checkType('findNamespaceId', 1, link, 'string')
	checkType('findNamespaceId', 2, removeColon, 'boolean', true)
	if removeColon ~= false then
		link = removeInitialColon(link)
	end
	local namespace = link:match('^(.-):')
	if namespace then
		local nsTable = mw.site.namespaces[namespace]
		if nsTable then
			return nsTable.id
		end
	end
	return 0
end

function p.formatPages(...)
	-- Formats a list of pages using formatLink and returns it as an array. Nil
	-- values are not allowed.
	local pages = {...}
	local ret = {}
	for i, page in ipairs(pages) do
		ret[i] = p._formatLink(page)
	end
	return ret
end

function p.formatPageTables(...)
	-- Takes a list of page/display tables and returns it as a list of
	-- formatted links. Nil values are not allowed.
	local pages = {...}
	local links = {}
	for i, t in ipairs(pages) do
		checkType('formatPageTables', i, t, 'table')
		local link = t[1]
		local display = t[2]
		links[i] = p._formatLink(link, display)
	end
	return links
end

function p.makeWikitextError(msg, helpLink, addTrackingCategory)
	-- Formats an error message to be returned to wikitext. If
	-- addTrackingCategory is not false after being returned from
	-- [[Module:Yesno]], and if we are not on a talk page, a tracking category
	-- is added.
	checkType('makeWikitextError', 1, msg, 'string')
	checkType('makeWikitextError', 2, helpLink, 'string', true)
	yesno = require('Module:Yesno')
	local title = mw.title.getCurrentTitle()
	-- Make the help link text.
	local helpText
	if helpLink then
		helpText = ' ([[' .. helpLink .. '|help]])'
	else
		helpText = ''
	end
	-- Make the category text.
	local category
	if not title.isTalkPage and yesno(addTrackingCategory) ~= false then
		category = 'Hatnote templates with errors'
		category = string.format(
			'[[%s:%s]]',
			mw.site.namespaces[14].name,
			category
		)
	else
		category = ''
	end
	return string.format(
		'<strong class="error">Error: %s%s.</strong>%s',
		msg,
		helpText,
		category
	)
end

--------------------------------------------------------------------------------
-- Format link
--
-- Makes a wikilink from the given link and display values. Links are escaped
-- with colons if necessary, and links to sections are detected and displayed
-- with " § " as a separator rather than the standard MediaWiki "#". Used in
-- the {{format hatnote link}} template.
--------------------------------------------------------------------------------

function p.formatLink(frame)
	local args = getArgs(frame)
	local link = args[1]
	local display = args[2]
	if not link then
		return p.makeWikitextError(
			'no link specified',
			'Template:Format hatnote link#Errors',
			args.category
		)
	end
	return p._formatLink(link, display)
end

function p._formatLink(link, display)
	-- Find whether we need to use the colon trick or not. We need to use the
	-- colon trick for categories and files, as otherwise category links
	-- categorise the page and file links display the file.
	checkType('_formatLink', 1, link, 'string')
	checkType('_formatLink', 2, display, 'string', true)
	link = removeInitialColon(link)
	local namespace = p.findNamespaceId(link, false)
	local colon
	if namespace == 6 or namespace == 14 then
		colon = ':'
	else
		colon = ''
	end

	-- Find whether a faux display value has been added with the {{!}} magic
	-- word.
	if not display then
		local prePipe, postPipe = link:match('^(.-)|(.*)$')
		link = prePipe or link
		display = postPipe
	end

	-- Find the display value.
	if not display then
		local page, section = link:match('^(.-)#(.*)$')
		if page then
			display = page .. ' § ' .. section
		end
	end

	-- Assemble the link.
	if display then
		return string.format('[[%s%s|%s]]', colon, link, display)
	else
		return string.format('[[%s%s]]', colon, link)
	end
end

--------------------------------------------------------------------------------
-- Hatnote
--
-- Produces standard hatnote text. Implements the {{hatnote}} template.
--------------------------------------------------------------------------------

function p.hatnote(frame)
	local args = getArgs(frame)
	local s = args[1]
	local options = {}
	if not s then
		return p.makeWikitextError(
			'no text specified',
			'Template:Hatnote#Errors',
			args.category
		)
	end
	options.extraclasses = args.extraclasses
	options.selfref = args.selfref
	options.inline = args.inline
	return p._hatnote(s, options)
end

function p._hatnote(s, options)
	checkType('_hatnote', 1, s, 'string')
	checkType('_hatnote', 2, options, 'table', true)
	local classes = {'hatnote'}
	local extraclasses = options.extraclasses
	local selfref = options.selfref
	if type(extraclasses) == 'string' then
		classes[#classes + 1] = extraclasses
	end
	if selfref then
		classes[#classes + 1] = 'selfref'
	end
	local tag = options.inline and 'span' or 'div'
	return string.format(
		'<%s class="%s">%s</%s>',
		tag,
		table.concat(classes, ' '),
		s,
		tag
	)
end

return p