Template:Convert/doc/parameter list
< Template:Convert | doc
Jump to navigation
Jump to search
Parameter options for {{convert}} | |||
---|---|---|---|
Option | =.. | Description | Note |
|abbr=in |
in | Use symbol for first (left-hand side) unit | Symbol ('abbreviation') |
|abbr=off |
off | Use name for all units | Symbol ('abbreviation') |
|abbr=none |
none | ||
|abbr=on |
on | Use symbol for all units | Symbol ('abbreviation') |
|abbr=out |
out | Use symbol for right-hand side unit (default) | Symbol ('abbreviation') |
|abbr=values |
values | Show only input and output numbers, not units | Parts only |
|abbr=~ |
~ | Shows both unit name and symbol | Symbol & name |
|adj=j |
j | Join number and unit name using " " instead of a space | Join values |
|adj=mid|x=... |
mid | User-specified text after the input unit; sets adj=on (adjective)
|
Word adding, adjective |
|adj=on |
on | Unit name is adjective (singular and hyphenated) | Grammar, adjective |
|adj=pre|x=... |
pre | User-specified text before input unit | Word adding |
|adj=ri0 |
ri0 | Round input with precision 0 | Rounding and sigfig |
|adj=ri1 |
ri1 | Round input with precision 1 | Rounding and sigfig |
|adj=ri2 |
ri2 | Round input with precision 2 | Rounding and sigfig |
|adj=ri3 |
ri3 | Round input with precision 3 | Rounding and sigfig |
|disp=b |
b | Join input and output using " (...)" (default) | Join values |
|disp=sqbr |
sqbr | Join input and output using " [...]" | Join values |
|disp=br |
br | Join input and output using "<br/>" | Join values |
|disp=comma |
comma | Join input and output using ", " | Join values |
|disp=or |
or | Join input and output using " or " | Join values |
|disp=number |
number | Display output number only | Parts only |
|disp=output number only |
output number only | ||
|disp=out |
out | Display only output number and name/symbol | Parts only |
|disp=output only |
output only | ||
|disp=preunit|x=... |
preunit | User-specified text before input and output units | Word adding |
|disp=table |
table | Output is suitable for a table cell with align="right" | Table columns |
|disp=tablecen |
tablecen | Output is suitable for a table cell with align="center" | Table columns |
|disp=unit |
unit | Display input name/symbol only ( not input number, not output) | Parts only |
|disp=unit2 |
unit2 | Display output name/symbol only (not input; not output number) | Parts only |
|disp=x|... |
x | Join input and output using user-specified text | Word adding |
|comma=5 |
05 | Only use comma for thousands separator if 5 or more digits | Number format |
|comma=gaps |
gaps | Use gaps (space), not comma, for thousands separator | Number format |
|comma=gaps5 |
gaps5 | Use gaps (space), but only if 5 or more digits | Number format |
|comma=off |
off | No thousands separator | Number format |
|frac=N |
N | Show imperial number in fractions, denominator=N | Number format, fraction |
|lk=in |
in | Link left-hand side unit name or symbol | Unit link |
|lk=on |
on | Link all unit names or symbols (but not twice for the same unit) | Unit link |
|lk=out |
out | Link right-hand side unit name or symbol | Unit link |
|order=flip |
flip | Inverts order of input, output measurements (conversion first) | Order |
|round=5 |
05 | Rounds calculation to the nearest multiple of 5 | Rounding and sigfig |
|round=25 |
25 | Rounds calculation to the nearest multiple of 25 | Rounding and sigfig |
|round=each |
each | In a range, each number is rounded by the default rounding | Rounding and sigfig |
|sigfig=N |
N | Round output number to N significant figures (N is a positive integer) | Rounding and sigfig |
|sortable=in |
in | Output numeric hidden sort field for use in a sortable table (based on input) | Table sort |
|sortable=on |
on | ||
|sortable=out |
out | Output numeric hidden sort field for use in a sortable table (based on output) | Table sort |
|sp=us |
us | Use U.S. spelling (like "meter" instead of default "metre") | Spelling U.S. names |
|spell=in |
in | Spell input number in words | Spelling numbers |
|spell=In |
In | Spell input number in words with first letter uppercase | Spelling numbers |
|spell=on |
on | Spell input and output numbers in words | Spelling numbers |
|spell=On |
On | Spell input and output numbers in words with first letter uppercase | Spelling numbers |
|$=€ |
$ | Replace $-sign with a currency sign, for example in $/acre (no currency conversion happens)
|
Cost per unit |
|debug=yes |
yes | Debugging only. In a sortable table: show the normally hidden sort key | Table sort |
|abbr=comma |
comma | Deprecated. Use |comma=off | Number format |
|abbr=mos |
mos | Deprecated. Use |x| or |by| | Range format |
|adj=1 |
01 | Deprecated. Do not use. No need to deviate from MOS regarding plurals | Plural or singular |
|adj=flip |
flip | Deprecated. Use |order=flip | Order |
|adj=nocomma |
nocomma | Deprecated. Use |comma=off | Number format |
|disp=2 |
02 | Deprecated. Use |disp=output only | Parts only |
|disp=5 |
05 | Deprecated. Use |round=5 | Rounding and sigfig |
|disp=flip |
flip | Deprecated. Use |order=flip | Order |
|disp=flip5 |
flip5 | Deprecated. Use |order=flip |round=5 | Order, rounding |
|disp=nocomma |
nocomma | Deprecated. Use |comma=off | Number format |
|disp=u2 |
u2 | Deprecated. Use |disp=unit2 | Parts only |
|near=5 |
05 | Deprecated. Use |round=5 | Rounding and sigfig |
Template documentation[create]
Editors can experiment in this template's sandbox (create | mirror) and testcases (create) pages. Please add categories to the /doc subpage. Subpages of this template. |