Difference between revisions of "Acid Bench 80"

From LNF Wiki
Jump to navigation Jump to search
Line 10: Line 10:
 
|mask =
 
|mask =
 
|size =
 
|size =
|chemicals =
+
chemicals = [[Acetic Acid|Acetic Acid (C<sub>2</sub>H<sub>4</sub>O<sub>2</sub>)]]
 +
 
 +
[[Aluminum Etch|Aluminum Etch]]
 +
 
 +
[[Buffered HF|Buffered HF (BHF)]]
 +
 
 +
[[Hydrofluoric acid|Hydrofluoric acid (HF)]]
 +
 
 +
[[Chromium Etch|Chromium Etch]]
 +
 
 +
[[Hydrochloric acid|Hydrochloric acid (HCl)]]
 +
 
 +
[[Hydrogen peroxide|Hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>)]]
 +
 
 +
[[Gold Etch|Gold Etch]]
 +
 
 +
[[Nanostrip|Nanostrip]]
 +
 
 +
[[Nitric acid|Nitric acid (HNO<sub>3</sub>)]]
 +
 
 +
[[Phosphoric Acid|Phosphoric Acid (H<sub>3</sub>O<sub>4</sub>P)]]
 +
 
 +
[[Sulfuric acid|Sulfuric acid (H<sub>2</sub>SO<sub>4</sub>)]]
 +
 
 
|gases =  
 
|gases =  
 
|overview = [[{{PAGENAME}}#System_overview | System Overview]]
 
|overview = [[{{PAGENAME}}#System_overview | System Overview]]
|sop = [https://link.to.google.doc/preview SOP]
+
|sop = [https://docs.google.com/document/d/1AduVT6p3tAV6EG-5MHiml61evDzBGSkPUws4AL0k1xw/preview SOP]
|processes = [[{{PAGENAME}}/Processes|Supported Processes]]
+
<!--|processes = [[{{PAGENAME}}/Processes|Supported Processes]]
|userprocesses = [[LNF_User:{{PAGENAME}}_user_processes|User Processes]]
+
|userprocesses = [[LNF_User:{{PAGENAME}}_User_Processes|User Processes]] -->
 
|maintenance = [[{{PAGENAME}}#Maintenance | Maintenance]]
 
|maintenance = [[{{PAGENAME}}#Maintenance | Maintenance]]
 
}}
 
}}
 
 
{{warning|This page has not been released yet.}}
 
{{warning|This page has not been released yet.}}
  

Revision as of 10:18, 10 March 2020

Acid Bench 80

[[File:

          1. .jpg|center|300px]]
Equipment Details
Technology Process Technology
Materials Restriction Undefined
Sample Size

chemicals = Acetic Acid (C2H4O2)

Aluminum Etch

Buffered HF (BHF)

Hydrofluoric acid (HF)

Chromium Etch

Hydrochloric acid (HCl)

Hydrogen peroxide (H2O2)

Gold Etch

Nanostrip

Nitric acid (HNO3)

Phosphoric Acid (H3O4P)

Sulfuric acid (H2SO4)
Equipment Manual
Overview System Overview
Operating Procedure SOP
Maintenance Maintenance


Warning Warning: This page has not been released yet.

The Acid Bench 80 is a wet bench used for working with acids, mostly for etching and cleaning of samples that have had metals and/or polymers on them. It is considered a Metals class tool, so wafers with metal are allowed in the bench with some restrictions. It is intended for use with mixed materials and all substrate sizes up to 6 inches with the main focus being on piece parts.

Announcements

  • Update this with announcements as necessary

Capabilities

  • Etch Rate
  • Resolution
  • Aspect Ratio
  • Thickness range

System overview

Hardware details

  • Gases
  • Pressure
  • Chuck
  • Chamber
  • RF / Power Specs
  • Chemicals

Substrate requirements

  • Wafer Size
  • Wafer type
  • Any mounting?
  • Wafer thickness

Material restrictions

The Acid Bench 80 is designated as a Undefined class tool. Below is a list of approved materials for the tool. Approved means the material is allowed in the tool under normal circumstances. If a material is not listed, please create a helpdesk ticket or email info@lnf.umich.edu for any material requests or questions.


Supported processes

There are several processes for this tool supported by the LNF, which are described in more detail on the Processes page.

In addition to these, this tool has a number of user-created recipes for etching a wide variety of materials. Some of these recipes are documented on Acid Bench 80 user processes. If you are curious if your material can be processed in this tool, please contact the tool engineers via the helpdesk ticket system.

Standard operating procedure

Widget text will go here.

Checkout procedure

  1. Read through this page and the Standard Operating Procedure above.
  2. Complete the training request form here.
  3. Create a [http://ssel-sched.eecs.umich.edu/sselScheduler/ResourceContact.aspx?tabindex=3&path=0:0:0:
          1. Helpdesk Ticket] requesting training.
  4. A tool engineer will schedule a time for initial training.
  5. Practice with your mentor or another authorized user until you are comfortable with tool operation.
  6. Complete the SOP quiz here.
  7. Schedule a checkout session with a tool engineer via the helpdesk ticket system. If this checkout is successful, the engineer will authorize you on the tool.

Maintenance

Process name