Difference between revisions of "Aluminum"
Line 15: | Line 15: | ||
Process technologies that can be used to deposit/pattern this material. If this is a substrate, refer to what tool/process restrictions there may be and possibly remove the following sub-sections. | Process technologies that can be used to deposit/pattern this material. If this is a substrate, refer to what tool/process restrictions there may be and possibly remove the following sub-sections. | ||
− | + | ===Deposition Equipment=== | |
− | + | *[[Lab 18-2]] | |
− | + | *[[Enerjet Evaporator]] | |
− | + | *[[Angstrom Engineering Evovac Evaporator]] | |
− | + | *[[PVD 75 Proline]] | |
===Etching Equipment=== | ===Etching Equipment=== | ||
− | + | *[[Acid Bench 12]] - maintained tank | |
− | + | *[[Acid Bench 73]] - Beaker | |
− | + | *[[Acid Bench 82]] - Beaker | |
==Processes== | ==Processes== |
Revision as of 10:57, 1 April 2020
This page has not been released yet. |
Aluminum | |
---|---|
Material Details | |
Material Restriction | Undefined |
Aluminum is a metal that is a silvery-white, soft, non-magnetic and ductile in the boron group.
Contents
Processing Tools
Process technologies that can be used to deposit/pattern this material. If this is a substrate, refer to what tool/process restrictions there may be and possibly remove the following sub-sections.
Deposition Equipment
Etching Equipment
- Acid Bench 12 - maintained tank
- Acid Bench 73 - Beaker
- Acid Bench 82 - Beaker
Processes
Atomic Layer Deposition (ALD)
Atomic layer deposition (ALD) is a type of chemical vapor deposition (CVD) where the reactions are limited to the surface of the object being coated. Instead of flowing two or more gasses into the chamber and letting them react on or near the surface of the substrate as in CVD, in ALD the individual chemical components are introduced to the deposition chamber one at a time. Because the reaction is surface-limited, ALD creates extremely conformal films with well controlled thickness. Unfortunately, in order to limit CVD in the chamber, gasses must be pumped out completely between each dose, making the process very slow and only useful for very thin films.
E-beam evaporation
Electron beam evaporation (e-beam evaporation) is a form of physical vapor deposition in which a target anode is bombarded with an electron beam given off by a tungsten filament under high vacuum. The accelerated electrons strike the target and melt/sublimate the material to transform into the gaseous phase. These atoms then precipitate into solid form, coating everything in the vacuum chamber (within line of sight) with a thin layer of the anode material.
Sputter deposition
Sputter deposition is a physical vapor deposition method of thin film deposition in which a high-purity source material (called a cathode or target) is subjected to a gas plasma (typically argon). The energetic atoms in this gas plasma collide with the target material and knock off source atoms which then travel to the substrate and condense into a thin film.
Etch Processes
Wet etching
Wet etching can be used to etch aluminum using Aluminum Etch
References
- Etch rates for micromachining processing https://ieeexplore.ieee.org/abstract/document/546406
- Etch rates for micromachining processing-Part II https://ieeexplore.ieee.org/abstract/document/1257354