Difference between revisions of "Aluminum"

From LNF Wiki
Jump to navigation Jump to search
 
(34 intermediate revisions by 3 users not shown)
Line 2: Line 2:
 
{{warning|This page has not been released yet.}}
 
{{warning|This page has not been released yet.}}
 
{{#vardefine:restriction|0}} <!-- Set the Material Restriction Level: 1 = CMOS Clean, 2 = Semi-Clean, 3 = Metals, 4 = varies -->
 
{{#vardefine:restriction|0}} <!-- Set the Material Restriction Level: 1 = CMOS Clean, 2 = Semi-Clean, 3 = Metals, 4 = varies -->
{{Infobox material
+
Aluminum is a metal that is a silvery-white, soft, non-magnetic and ductile in the boron group.
|image      =
+
==Processing Equipment==
|caption    =  
+
Process technologies that can be used to deposit/pattern this material.  If this is a substrate, refer to what tool/process restrictions there may be and possibly remove the following sub-sections.
|category  =
+
===Deposition Equipment===
|properties =
+
*[[Lab 18-2]]
|names      =
+
*[[Enerjet Evaporator]]
}}
+
*[[Angstrom Engineering Evovac Evaporator]]
 +
*[[PVD 75 Proline]]
 +
 
 +
===Etching Equipment===
 +
*[[Acid Bench 12]] - maintained tank
 +
*[[Acid Bench 73]] - Beaker
 +
*[[Acid Bench 80]] - Beaker
 +
*[[LAM 9400]]
  
Aluminium is a metal that is a silvery-white, soft, non-magnetic and ductile in the boron group.
+
===Characterization Equipment===
 +
*[[Dektak XT]]
  
==Processing Tools==
+
==Applications==
Process technologies that can be used to deposit/pattern this material.  If this is a substrate, refer to what tool/process restrictions there may be and possibly remove the following sub-sections.
+
*Aluminum is a commonly deposited metal in the lab. It has a high reflectivity for optical devices.
  
===Deposition Equipment===
+
==Processes==
 +
===Depositoin Processes===
 +
*[[Electron_beam_evaporation|E-beam evaporation]]
  
===Etching Equipment===
+
*[[Sputter_deposition|Sputter deposition]]
* Wet Etching
 
**[[Acid Bench 12]] - maintained tank
 
**[[Acid Bench 73]] - Beaker
 
**[[Acid Bench 82]] - Beaker
 
  
===Processes===
+
===Etch Processes===
* List of processes for this material
+
*[[Wet etching|Wet etching]]
===Deposition===
+
**Wet etching can be used to etch aluminum using [[Aluminum Etch]] at [[Acid Bench 12]], [[Acid Bench 73]], and [[ Acid Bench 80]].
 +
*[[Reactive ion etching]]
  
===Etching===
+
===Characterization Processes===
Chemical etching is done using [[Aluminum Etch]]
+
*The profilometer can be used to measure the thickness of your deposition.
  
 
==References==
 
==References==
*Citations/references for this material
+
*'''Etch rates for micromachining processing''' https://ieeexplore.ieee.org/abstract/document/546406
 +
*'''Etch rates for micromachining processing-Part II''' https://ieeexplore.ieee.org/abstract/document/1257354

Latest revision as of 09:02, 22 April 2020

Warning Warning: This page has not been released yet.

Aluminum is a metal that is a silvery-white, soft, non-magnetic and ductile in the boron group.

Processing Equipment

Process technologies that can be used to deposit/pattern this material. If this is a substrate, refer to what tool/process restrictions there may be and possibly remove the following sub-sections.

Deposition Equipment

Etching Equipment

Characterization Equipment

Applications

  • Aluminum is a commonly deposited metal in the lab. It has a high reflectivity for optical devices.

Processes

Depositoin Processes

Etch Processes

Characterization Processes

  • The profilometer can be used to measure the thickness of your deposition.

References