Difference between revisions of "Aluminum"

From LNF Wiki
Jump to navigation Jump to search
 
(2 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
{{#vardefine:restriction|0}} <!-- Set the Material Restriction Level: 1 = CMOS Clean, 2 = Semi-Clean, 3 = Metals, 4 = varies -->
 
{{#vardefine:restriction|0}} <!-- Set the Material Restriction Level: 1 = CMOS Clean, 2 = Semi-Clean, 3 = Metals, 4 = varies -->
 
Aluminum is a metal that is a silvery-white, soft, non-magnetic and ductile in the boron group.  
 
Aluminum is a metal that is a silvery-white, soft, non-magnetic and ductile in the boron group.  
==Applications==
 
*Discuss common uses/applications for this material. Why this materials is used in the LNF?
 
 
 
==Processing Equipment==
 
==Processing Equipment==
 
Process technologies that can be used to deposit/pattern this material.  If this is a substrate, refer to what tool/process restrictions there may be and possibly remove the following sub-sections.
 
Process technologies that can be used to deposit/pattern this material.  If this is a substrate, refer to what tool/process restrictions there may be and possibly remove the following sub-sections.
 
 
===Deposition Equipment===
 
===Deposition Equipment===
 
*[[Lab 18-2]]
 
*[[Lab 18-2]]
Line 20: Line 16:
 
*[[Acid Bench 80]] - Beaker
 
*[[Acid Bench 80]] - Beaker
 
*[[LAM 9400]]
 
*[[LAM 9400]]
 +
 +
===Characterization Equipment===
 +
*[[Dektak XT]]
 +
 +
==Applications==
 +
*Aluminum is a commonly deposited metal in the lab. It has a high reflectivity for optical devices.
 +
 
==Processes==
 
==Processes==
 
===Depositoin Processes===
 
===Depositoin Processes===
Line 30: Line 33:
 
**Wet etching can be used to etch aluminum using [[Aluminum Etch]] at [[Acid Bench 12]], [[Acid Bench 73]], and [[ Acid Bench 80]].  
 
**Wet etching can be used to etch aluminum using [[Aluminum Etch]] at [[Acid Bench 12]], [[Acid Bench 73]], and [[ Acid Bench 80]].  
 
*[[Reactive ion etching]]
 
*[[Reactive ion etching]]
 +
 +
===Characterization Processes===
 +
*The profilometer can be used to measure the thickness of your deposition.
  
 
==References==
 
==References==
 
*'''Etch rates for micromachining processing''' https://ieeexplore.ieee.org/abstract/document/546406
 
*'''Etch rates for micromachining processing''' https://ieeexplore.ieee.org/abstract/document/546406
 
*'''Etch rates for micromachining processing-Part II''' https://ieeexplore.ieee.org/abstract/document/1257354
 
*'''Etch rates for micromachining processing-Part II''' https://ieeexplore.ieee.org/abstract/document/1257354

Latest revision as of 08:02, 22 April 2020

Warning Warning: This page has not been released yet.

Aluminum is a metal that is a silvery-white, soft, non-magnetic and ductile in the boron group.

Processing Equipment

Process technologies that can be used to deposit/pattern this material. If this is a substrate, refer to what tool/process restrictions there may be and possibly remove the following sub-sections.

Deposition Equipment

Etching Equipment

Characterization Equipment

Applications

  • Aluminum is a commonly deposited metal in the lab. It has a high reflectivity for optical devices.

Processes

Depositoin Processes

Etch Processes

Characterization Processes

  • The profilometer can be used to measure the thickness of your deposition.

References