Open main menu

Everbeing BD-6 Probe Station

Revision as of 09:23, 24 March 2021 by Bkarmstr (talk | contribs) (Created page with "<!-- Set the resource ID, 5 digit # found on the scheduler --> {{#vardefine:toolid|#####}} <!-- Set the Process Technology (see subcategories on Equipment page) --> {{#vard...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

The Everbeing BD-6 Probe Station is a probe station.

Everbeing BD-6 Probe Station

[[File:

          1. .jpg|center|300px]]
Equipment Details
Technology Metrology
Materials Restriction Metals
Sample Size pieces up to 6" wafers
Equipment Manual
Overview System Overview
Operating Procedure SOP
Supported Processes Supported Processes
User Processes User Processes
Maintenance Maintenance


Warning Warning: This page has not been released yet.

Contents

Announcements

  • Update this with announcements as necessary

Capabilities

  • Etch Rate
  • Resolution
  • Aspect Ratio
  • Thickness range

System overview

Hardware details

  • Gases
  • Pressure
  • Chuck
  • Chamber
  • RF / Power Specs
  • Chemicals

Substrate requirements

  • Wafer Size
  • Wafer type
  • Any mounting?
  • Wafer thickness

Material restrictions

The Everbeing BD-6 Probe Station is designated as a Metals class tool. Below is a list of approved materials for the tool. Approved means the material is allowed in the tool under normal circumstances. If a material is not listed, please create a helpdesk ticket or email info@lnf.umich.edu for any material requests or questions.


Supported processes

There are several processes for this tool supported by the LNF, which are described in more detail on the Processes page.

In addition to these, this tool has a number of user-created recipes for etching a wide variety of materials. Some of these recipes are documented on Everbeing BD-6 Probe Station user processes. If you are curious if your material can be processed in this tool, please contact the tool engineers via the helpdesk ticket system.

Standard operating procedure

Widget text will go here.

Checkout procedure

  1. Read through this page and the Standard Operating Procedure above.
  2. Complete the training request form here.
  3. Create a [http://ssel-sched.eecs.umich.edu/sselScheduler/ResourceContact.aspx?tabindex=3&path=0:0:0:
          1. Helpdesk Ticket] requesting training.
  4. A tool engineer will schedule a time for initial training.
  5. Practice with your mentor or another authorized user until you are comfortable with tool operation.
  6. Complete the SOP quiz here.
  7. Schedule a checkout session with a tool engineer via the helpdesk ticket system. If this checkout is successful, the engineer will authorize you on the tool.

Maintenance

Process name