Difference between revisions of "GCA AS200 AutoStep"
Line 21: | Line 21: | ||
{{warning|This page has not been released yet.}} | {{warning|This page has not been released yet.}} | ||
− | + | The GCA AS200 Auto Step is a submicron capable projection lithography 5X reduction exposure system. The system can automatically perform all wafer processing and handling operations of 4" wafers and can be used to align and expose pieces. It is primarily used to expose an array of images directly onto the surface of a wafer. | |
+ | |||
==Announcements== | ==Announcements== |
Revision as of 11:16, 25 August 2015
GCA AS200 AutoStep | |
---|---|
Equipment Details | |
Technology | Projection Lithography |
Materials Restriction | Metals |
Equipment Manual | |
Overview | System Overview |
Operating Procedure | SOP |
Supported Processes | Supported Processes |
User Processes | User Processes |
Maintenance | Maintenance |
This page has not been released yet. |
The GCA AS200 Auto Step is a submicron capable projection lithography 5X reduction exposure system. The system can automatically perform all wafer processing and handling operations of 4" wafers and can be used to align and expose pieces. It is primarily used to expose an array of images directly onto the surface of a wafer.
Contents
Announcements
- Update this with announcements as necessary
Capabilities
- Etch Rate
- Resolution
- Aspect Ratio
- Thickness range
System overview
Hardware details
- Gases
- Pressure
- Chuck
- Chamber
- RF / Power Specs
- Chemicals
Substrate requirements
- Wafer Size
- Wafer type
- Any mounting?
- Wafer thickness
Material restrictions
The GCA AS200 AutoStep is designated as a Metals class tool. Below is a list of approved materials for the tool. Approved means the material is allowed in the tool under normal circumstances. If a material is not listed, please create a helpdesk ticket or email info@lnf.umich.edu for any material requests or questions.
Supported processes
There are several processes for this tool supported by the LNF, which are described in more detail on the Processes page.
In addition to these, this tool has a number of user-created recipes for etching a wide variety of materials. Some of these recipes are documented on GCA AS200 AutoStep user processes. If you are curious if your material can be processed in this tool, please contact the tool engineers via the helpdesk ticket system.
Standard operating procedure
Widget text will go here.
Checkout procedure
- Read through this page and the Standard Operating Procedure above.
- Complete the training request form here.
- Create a Helpdesk Ticket requesting training.
- A tool engineer will schedule a time for initial training.
- Practice with your mentor or another authorized user until you are comfortable with tool operation.
- Complete the SOP quiz here.
- Schedule a checkout session with a tool engineer via the helpdesk ticket system. If this checkout is successful, the engineer will authorize you on the tool.
Maintenance
Process name