+ | Steps: | ||
+ | #[[Optical_lithography | Normal cleaning and HMDS]] | ||
+ | #Spin normally to achieve the appropriate thickness | ||
+ | #Standard softbake | ||
+ | #Standard exposure based on thickness of the resist, substrate reflectivity, and the tool that is used | ||
+ | #Run Recipe 2 on the [[Image Reversal Oven]] | ||
+ | #Flood expose | ||
+ | ##Use MA6/BA6 | ||
+ | ##Flood Exposure setting. Make sure is is set up before loading the wafer | ||
+ | ##Twice normal exposure for thickness of the resist, and substrate reflectivity | ||
+ | ##A mask plate or the plate holder is not needed | ||
+ | ##Load wafer onto stage and hit load, it will cycle through and expose substrate | ||
+ | #Develop shorter time than normal, typically half the normal time | ||
+ | #Inspect | ||
==Limitations?== | ==Limitations?== |
Revision as of 12:50, 27 February 2017
This page has not been released yet. |
About this Process | |
---|---|
Process Details | |
Equipment | Image reversal |
Technology | Lithography |
Chemicals Used | Photoresist |
Gases Used | NH3 |
Image reversal is a process to reverse the tone of positive photoresists. Similar to a negative photoresist, areas that are exposed become "protected", while the unexposed areas will be developed away. After exposure, the sample is exposed to ammonia, which reacts with the exposed areas making them impervious to the developer solution. The sample is then flood exposed, which allows the areas that were not exposed initially (and therefore not affected by the ammonia) to be developed. This process is commonly used to create clear field masks but can also be used with most standard photoresists on any sample.
Contents
Procedure
The image reversal procedure includes the standard lithography steps with the addition of the ammonia exposure and flood exposure. Please see the section below for specifics with certain photoresists.
- Photoresist application and softbake
- Sample exposure
- Ammonia treatment
- Flood exposure
- Photoresist development
Ammonia treatment
The sample is heated and exposed to ammonia using the Image Reversal Oven. Details about how the ammonia works
Flood exposure
...
Common applications
Some sort of intro
Mask reversal
- Standard exposure based on the Heidelberg µPG 501 Mask Maker
- Run Recipe 2 on the Image Reversal Oven
- Flood expose
- Use MA6/BA6
- Flood Exposure setting. Make sure is is set up before loading the mask
- 3s exposure
- A mask plate or the plate holder is not needed
- Load mask onto stage chrome and photoresist side up and hit load, it will cycle through and expose substrate
- Develop shorter time than normal, typically half the normal time
- Inspect
SPR 220
Steps:
- Normal cleaning and HMDS
- Spin normally to achieve the appropriate thickness
- Standard softbake (for 3-5um 90s @ 115C)
- Standard exposure based on thickness of the resist, substrate reflectivity, and the tool that is used
- Standard Post Exposure Bake (for 3-5um 90s @ 115C)
- Run Recipe 2 on the Image Reversal Oven
- Flood expose
- Use MA6/BA6
- Flood Exposure setting. Make sure is is set up before loading the wafer
- Twice normal exposure for thickness of the resist, and substrate reflectivity
- A mask plate or the plate holder is not needed
- Load wafer onto stage and hit load, it will cycle through and expose substrate
- Standard Post Exposure Bake (for 3-5um 90s @ 115C)
- Develop shorter time than normal, typically half the normal time
- Inspect
Shipley 1800 series
Steps:
- Normal cleaning and HMDS
- Spin normally to achieve the appropriate thickness
- Standard softbake
- Standard exposure based on thickness of the resist, substrate reflectivity, and the tool that is used
- Run Recipe 2 on the Image Reversal Oven
- Flood expose
- Use MA6/BA6
- Flood Exposure setting. Make sure is is set up before loading the wafer
- Twice normal exposure for thickness of the resist, and substrate reflectivity
- A mask plate or the plate holder is not needed
- Load wafer onto stage and hit load, it will cycle through and expose substrate
- Develop shorter time than normal, typically half the normal time
- Inspect