Parameters

Parameter Breakthrough Etch
Pressure 100 mTorr 12 mTorr
TCP Power 300 W 500 W
Bias Power 50 W 30 W
Cl2 Flow 100 sccm 0 sccm
C4F8 Flow 0 sccm 100 sccm
He Flow 0 sccm 100 sccm
HBr 0 sccm 100 sccm

Capabilities

Etch Rate

Mask Selectivity

Sidewall Profile

Limitations