Difference between revisions of "Lab 18-2"

From LNF Wiki
Jump to navigation Jump to search
Line 6: Line 6:
 
|materials = [[Silicon|Si]]
 
|materials = [[Silicon|Si]]
 
|mask = [[Photoresist|PR]], [[Silicon Dioxide|SiO<sub>2</sub>]]
 
|mask = [[Photoresist|PR]], [[Silicon Dioxide|SiO<sub>2</sub>]]
|size = 150mm by 4mm and smaller samples
+
|size = 150mm x 4mm and smaller samples
 
|gases = [[Ar]], [[N2|N<sub>2</sub>]], [[O2|O<sub>2</sub>]]
 
|gases = [[Ar]], [[N2|N<sub>2</sub>]], [[O2|O<sub>2</sub>]]
 
|overview = [https://docs.google.com/a/lnf.umich.edu/document/d/1UZYJ8unAjQOIJ3nJpa1fwXxYKMyW12k6eDR-A-P6fIE/preview System Overview]
 
|overview = [https://docs.google.com/a/lnf.umich.edu/document/d/1UZYJ8unAjQOIJ3nJpa1fwXxYKMyW12k6eDR-A-P6fIE/preview System Overview]

Revision as of 15:43, 16 February 2015


Lab 18-2
61081.jpg
Equipment Details
Technology PVD
Materials Restriction Undefined
Material Processed Si
Mask Materials PR, SiO2
Sample Size 150mm x 4mm and smaller samples
Gases Used Ar, N2, O2
Equipment Manual
Overview System Overview
Operating Procedure SOP
Supported Processes Supported Processes
User Processes User Processes


Warning Warning: This page has not been released yet.

Lab 18-2 is a magnetron sputter deposition tool for depositing conductive metallic films.

Announcements

  • Update this with announcements as necessary

System Overview

Tool Capabilities/Limitations

  • Hardware Details
    • Power specs
    • Chemicals
    • Gases
  • Capabilities
    • Resolution
    • Aspect Ratio
    • Thickness range

Substrate Requirements

  • Sample size range
    • Diameter
    • Thickness

Material Restrictions

  • materials allowed
  • materials not allowed

Supported Processes

There are several recipes supported by the LNF, including an oxide etch, nitride etch, and polysilicon etch. For more details, see Lab 18-2/Processes.

In addition to these, this tool has a number of user-created recipes for etching a wide variety of materials. Some of these recipes are documented on [LAM 9400 User Processes]. If you are curious if your material can be etched in this tool, please contact the tool engineers via the helpdesk ticket system.

Standard Operating Procedure

Checkout Procedure

  1. Read through the Standard Operating Procedure above.
  2. Complete the training request form [<link> here].
  3. Create a helpdesk ticket requesting training.
  4. A tool engineer will schedule a time for initial training.
  5. Practice with your mentor or another authorized user until you are comfortable with tool operation.
  6. Complete the SOP quiz [<link> here].
  7. Schedule a checkout session with a tool engineer via the helpdesk ticket system. If this checkout is successful, the engineer will authorize you on the tool.

Tool Qualification

Process Name