Module:Asbox
Jump to navigation
Jump to search
Documentation for this module may be created at Module:Asbox/doc
--[[
This module was created by User:CodeHydro (Alexander Zhikun He).
User:Jackmcbarn and User:Mr._Stradivarius provided a great deal of assistance in writting p.main()
p.main() draw heavily from the following version of Template:Asbox of the English Wikipedia, authored primarily by User:Rich_Farmbrough
https://en.wikipedia.org/w/index.php?title=Template:Asbox&oldid=619510287
p.templatepage() is derived from the following revision of Template:Asbox/templatepage, authored primarily by User:MSGJ
https://en.wikipedia.org/w/index.php?title=Template:Asbox/templatepage&oldid=632914791
Both templates had significant contributions from numerous others listed in the revision history tab of their respective pages.
--]]
local WRAPPER_TEMPLATE, args = 'Template:Asbox'
local p, Buffer, stubCats = {
--Prevents dupli-cats... get it? Maybe not?
cats = setmetatable({}, {__newindex = function(t, i, v)
if not rawget(t, i) then
rawset(t, i, v)
table.insert(t, i)
end
end}),
--initializes variables required by both p.main and p.templatepage
init = function(self, frame, page)
args, page = args or require('Module:Arguments').getArgs(frame, {
wrappers = WRAPPER_TEMPLATE
}), page or mw.title.getCurrentTitle()
--Ensures demo parameter will never affect category() output for articles
self.demo = self.demo or page.namespace ~= 0 and args.demo
return args, page
end
}, require('Module:Buffer')
--[[
Formats category links. Stores them until called with cat.done=true
Takes multiple or single categories in the form of 'cat'
or a table of strings and/or tables containing parts. (See below)
]]
local attention, catTag, catKey = Buffer'Stub message templates needing attention', '[[Category:%s]]', '%s|%s%s'
local function category(cat)
for _, v in ipairs((tostring(cat) == cat or cat.t) and {cat} or cat) do
--[[
If v is a table:
[1] = full category name; defaults to local attention if blank
k = Category sort key. Prefix before v.t
t = page.text or args.tempsort#; appended after k (or in its place if omitted). Required if v is not a string
Basically the same as v = (v[1] or attention) .. ' | ' .. (v.k or '') .. v.t
]]
if v and v ~= true then--reject v = nil, false, or true
p.cats[catTag:format(tostring(v) == v and
v
or (v[1] and Buffer(v[1]) or attention):_in(v.k):_(v.t):_str(2, nil, nil, '|')
)] = true
end
end
return cat.done and table.concat(p.cats, p.demo and ' | ' or nil) or ''
end
--[[
Makes an ombox warning;
Takes table {ifNot = Boolean, text, {cat. sort key, cat. sort name}}
Will return an empty string instead when ifNot evaluates to true
]]
local function ombox(v)
if v.ifNot then return end
p.ombox = p.ombox or require('Module:Message box').ombox
category{v[2]}
return p.ombox{
type = 'content',
text = v[1]
}
end
--[[
Unlike original template, module now takes unlimited cats! This function also performs
most stub category error checks except for the ombox for when main |category= is omitted (See p.template())
]]
local function catStub(page, pageDoc)
stubCats = {missing = {}, v = {}}
local code
for k, _ in pairs(args) do
--Find category parameters and store the number (main cat = '')
table.insert(stubCats, string.match(k, '^category(%d*)$'))
end
table.sort(stubCats)
for k, v in ipairs(stubCats) do
--Get category names and, if called by p.templatepage, the optional sort key
local tsort, cat = args['tempsort' .. v], mw.ustring.gsub(args['category' .. v], '[^%w%p%s]', '')--remove all hidden unicode chars
--Do not place template in main category if |tempsort = 'no'. However, DO place articles of that template in the main category.
table.insert(stubCats.v,
page and (--p.templatepage passes page; p.main does not, i.e. articles are categorized without sort keys.
v=='' and tsort == 'no'--if true, inserts 'true' in table, which category() will reject
or tsort and {cat, k = ' ', t = tsort}
or {cat, k = ' *', t = page.text}--note space in front of sort key
)
or cat
)
--Check category existance only if on the template page (i.e. stub documentation)
if page then
if not mw.title.new('Category:' .. cat).exists then
code = code or mw.html.create'code':wikitext'|category'
table.insert(stubCats.missing, tostring(mw.clone(code):wikitext(v)))
end
--[[
Checks non-demo stub template for documentation and flags if doc is present.
All stub cats names are checked and flagged if it does not match 'Category: [] stub'.
The main stub cat is exempt from the name check if the stub template has its own doc
(presumably, this doc would have an explanation as to why the main stub cat is non-conforming).
]]
table.insert(stubCats.v, v == '' and not p.demo and pageDoc.exists and
'Stub message templates with documentation subpages'
or not cat:match' stubs$' and {k = 'S', t = page.text}
)
end
end
--Add category names after loop is completed
category(stubCats.v)
return #stubCats.missing > 0 and ombox{
--Changed, original msg:
--One or more of the stub categories defined in this template do not seem to exist!
--Please double-check the parameters {{para|category}}, {{para|category1}} and {{para|category2}}.
'The following parameter'
.. (#stubCats.missing == 1 and ' defines a stub category that does' or 's define stub categories that do')
.. ' not exist: ' .. mw.text.listToText(stubCats.missing),
{k = 'N', t = page.text}
}
end
--Shows population of categories found by catStub(). Outputs demo values if none
local function population()
local wikitext, base = {}, '* [[:Category:%s]] (population: %s)\n'
if not args.category and stubCats[1] ~= false then
table.insert(stubCats, 1, false)
end
for _, v in ipairs(stubCats) do
table.insert(wikitext, base:format(
v and args['category' .. v] or '{{{category}}}',
v and mw.site.stats.pagesInCategory(args['category' .. v], 'all') or 0
))
end
return table.concat(wikitext)
end
--Includes standard stub documention and flags stub templates with bad parameter values.
function p.templatepage(frame, page)
args, page = p:init(frame, page)
local tStubDoc = mw.title.new'Template:Stub documentation'
local pageDoc = page:subPageTitle('doc')
--Reorganization note: Original Asbox alternates between outputting categories and checking on params |category#=.
--Rather than checking multiple times and switching tasks, all stub category param operations have been rolled into catStub()
return Buffer(
ombox{--Show ombox warnings for missing args.
ifNot = args.category,
'The <code>|category</code> parameter is not set. Please add an appropriate stub category.',
{k = 'C', t = page.text}
})
:_(ombox{
ifNot = args.subject or args.article or args.qualifier,
'This stub template contains no description! At least one of the parameters <code>|subject</code>, <code>|article</code> or <code>|qualifier</code> must be defined.',
{k = 'D', t = page.text}
})
:_(catStub(page, pageDoc))--catStub() may also return an ombox if there are non-existing categories
:_(category{
done = p.demo ~= 'doc',--Outputs categories if not doc demo
'Stub message templates',
'Exclude in print',
args.icon and
'Stub message templates using icon parameter'
or args.image and (
mw.title.new('Media:' .. mw.text.split(args.image, '|')[1]).exists--do nothing if exists. category() will reject true
or {k = 'B', t = page.text}
)
or 'Stub message templates without images',
args.imagealt and {k = 'I', t = page.text},
})
:_((not p.demo or p.demo == 'doc') and--Add standard stub template documentation
require('Module:Documentation').main{
content = Buffer(page.text ~= 'Stub' and--This comparison performed in {{Asbox/stubtree}} before it invokes Module:Asbox stubtree
require('Module:Asbox stubtree').subtree{args = {pagename = page.text}}
)
:_in'\n== About this template ==\nThis template is used to identify a':_(args.subject):_'stub':_(args.qualifier):_out' '--space
:_'. It uses {{[[Template:Asbox|asbox]]}}, which is a meta-template designed to ease the process of creating and maintaining stub templates.\n=== Usage ===\nTyping '
:_(mw.html.create'code'
:wikitext('{{', page.text == 'Stub' and 'stub' or page.text, '}}')
)
:_' produces the message shown at the beginning, and adds the article to the following categor'
:_(#stubCats > 1 and 'ies' or 'y')
:_':\n'
:_(population())
:_(pageDoc.exists and--transclusion of /doc if it exists
frame:expandTemplate{title = pageDoc.text}
)
:_'\n== General information ==\n'
:_(frame:expandTemplate{title = tStubDoc.text})
:_'\n\n'(),
['link box'] = Buffer'This documentation is automatically generated by [[Module:Asbox]].'
:_in'The general information is transcluded from [[Template:Stub documentation]]. '
:_(mw.html.create'span'
:cssText'font-size:smaller;font-style:normal;line-height:130%'
:node(('([%s edit] | [%s history])'):format(
tStubDoc:fullUrl('action=edit', 'relative'),
tStubDoc:fullUrl('action=history', 'relative')
))
)
:_out()
:_(page.protectionLevels.edit[1] == 'sysop' and
"This template is [[WP:PROTECT|fully protected]] and any [[WP:CAT|categories]] should be added to the template's ["
.. pageDoc:fullUrl('action=edit&preload=Template:Category_interwiki/preload', 'relative')
.. '| /doc] subpage, which is not protected.'
)' <br/>'
}
)()
end
function p.main(frame, page)
args, page = p:init(frame, page)
local output = mw.html.create'table'
:addClass'metadata plainlinks stub'
:css{background = 'transparent'}
:attr{role = 'presentation'}
:tag'tr'
:node((args.icon or args.image) and
mw.html.create'td'
:wikitext(args.icon or ('[[File:%s|%spx|alt=%s]]'):format(
args.image or '',
args.pix or '40x30',
args.imagealt or 'Stub icon'
))
)
:tag'td'
:tag'i'
:wikitext(
Buffer'This':_(args.subject):_(args.article or 'article'):_(args.qualifier)' ',--space
' is a [[Wikipedia:stub|stub]]. You can help Wikipedia by [',
page:fullUrl('action=edit', 'relative'),
' expanding it].'
)
:done()
:node(args.name and
require'Module:Navbar'._navbar{
args.name,
mini = 'yes',
style = 'position: absolute; right: 15px; display: none;'
}
)
:node(args.note and
mw.html.create()
:tag'br':done()
:tag'span'
:css{['font-style'] = 'normal', ['font-size'] = 'smaller'}
:wikitext(args.note)
:done()
)
:allDone()
--[[
Stub categories for templates include a sort key (Otherwise all will be indexed under the letter 'T' for 'Template:[] stubs')
Articles using the template do not need a sort key since they have unique names.
When p.demo equals 'doc', the demo stub categories will appear as those for a stub template.
Otherwise, any non-nil p.demo will emulate article space categories (plus any error cats unless set to 'art')
]]
if page.namespace == 0 then -- Main namespace
category'All stub articles'
catStub()
elseif p.demo then
if p.demo ~= 'doc' then catStub() end
--Unless p.demo is set to 'art', it will also include error categories normally only shown on
--the template but not in the article. The elseif after namespace == 0 means demo cats will never show in article space.
p.demodoc = p.demo ~= 'art' and p.templatepage(frame, page)
output = mw.html.create()
:node(output)
:tag'small':wikitext(
'Demo categories: ',
(category{done = true}:gsub('(%[%[)(Category:)([^|%]]-)(%|)', '%1%2%3|%2%3%4'):gsub('(%[%[)(Category:)', '%1:%2'))
):done()
:wikitext(p.demo == 'doc' and p.demodoc or nil)
else
--Checks for valid name; emulates original template's check using {{FULLPAGENAME:{{{name|}}}}}
local normalizedName = mw.title.new(args.name or '')
if normalizedName and normalizedName.fullText == page.fullText then
output = mw.html.create():node(output):wikitext(p.templatepage(frame, page))
elseif not page.isSubpage and page.namespace == 10 then-- Template namespace and not a subpage
category{{k = args.name and 'E' or 'W', t = page.text}}
end
end
return output:wikitext(not p.demo and category{done = true} or nil)
end
return p