Difference between revisions of "Module:Category handler/config"
Jump to navigation
Jump to search
[[commons:MediaWiki]]>MusikAnimal m (1 revision imported) |
m (1 revision imported) |
(No difference)
|
Latest revision as of 10:13, 3 April 2020
Documentation for this module may be created at Module:Category handler/config/doc
--------------------------------------------------------------------------------
-- [[Module:Category handler]] configuration data --
-- Language-specific parameter names and values can be set here. --
-- For blacklist config, see [[Module:Category handler/blacklist]]. --
--------------------------------------------------------------------------------
local cfg = {} -- Don't edit this line.
--------------------------------------------------------------------------------
-- Start configuration data --
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
-- Parameter names --
-- These configuration items specify custom parameter names. --
-- To add one extra name, you can use this format: --
-- --
-- foo = 'parameter name', --
-- --
-- To add multiple names, you can use this format: --
-- --
-- foo = {'parameter name 1', 'parameter name 2', 'parameter name 3'}, --
--------------------------------------------------------------------------------
cfg.parameters = {
-- The nocat and categories parameter suppress
-- categorisation. They are used with Module:Yesno, and work as follows:
--
-- cfg.nocat:
-- Result of yesno() Effect
-- true Categorisation is suppressed
-- false Categorisation is allowed, and
-- the blacklist check is skipped
-- nil Categorisation is allowed
--
-- cfg.categories:
-- Result of yesno() Effect
-- true Categorisation is allowed, and
-- the blacklist check is skipped
-- false Categorisation is suppressed
-- nil Categorisation is allowed
nocat = 'nocat',
categories = 'categories',
-- The parameter name for the legacy "category2" parameter. This skips the
-- blacklist if set to the cfg.category2Yes value, and suppresses
-- categorisation if present but equal to anything other than
-- cfg.category2Yes or cfg.category2Negative.
category2 = 'category2',
-- cfg.subpage is the parameter name to specify how to behave on subpages.
subpage = 'subpage',
-- The parameter for data to return in all namespaces.
all = 'all',
-- The parameter name for data to return if no data is specified for the
-- namespace that is detected.
other = 'other',
-- The parameter name used to specify a page other than the current page;
-- used for testing and demonstration.
demopage = 'page',
}
--------------------------------------------------------------------------------
-- Parameter values --
-- These are set values that can be used with certain parameters. Only one --
-- value can be specified, like this: --
-- --
-- cfg.foo = 'value name' -- --
--------------------------------------------------------------------------------
-- The following settings are used with the cfg.category2 parameter. Setting
-- cfg.category2 to cfg.category2Yes skips the blacklist, and if cfg.category2
-- is present but equal to anything other than cfg.category2Yes or
-- cfg.category2Negative then it supresses cateogrisation.
cfg.category2Yes = 'yes'
cfg.category2Negative = '¬'
-- The following settings are used with the cfg.subpage parameter.
-- cfg.subpageNo is the value to specify to not categorise on subpages;
-- cfg.subpageOnly is the value to specify to only categorise on subpages.
cfg.subpageNo = 'no'
cfg.subpageOnly = 'only'
--------------------------------------------------------------------------------
-- Default namespaces --
-- This is a table of namespaces to categorise by default. The keys are the --
-- namespace numbers. --
--------------------------------------------------------------------------------
cfg.defaultNamespaces = {
[ 0] = true, -- main
[ 6] = true, -- file
[ 12] = true, -- help
[ 14] = true, -- category
[100] = true, -- portal
[108] = true, -- book
}
--------------------------------------------------------------------------------
-- Wrappers --
-- This is a wrapper template or a list of wrapper templates to be passed to --
-- [[Module:Arguments]]. --
--------------------------------------------------------------------------------
cfg.wrappers = 'Template:Category handler'
--------------------------------------------------------------------------------
-- End configuration data --
--------------------------------------------------------------------------------
return cfg -- Don't edit this line.