Module:High-use
Revision as of 16:12, 27 March 2020 by [[commons:MediaWiki]]>CFCF (Restored older version)
Documentation for this module may be created at Module:High-use/doc
local p = {}
local _fetch = require('Module:Transclusion_count').fetch
function p.num(frame, count)
if count == nil then count = _fetch(frame) end
-- Build output string
local return_value = ""
if count == nil then
if frame.args[1] == "risk" then
return_value = "a very large number of"
else
return_value = "many"
end
else
-- Use 2 sigfigs for smaller numbers and 3 for larger ones
local sigfig = 2
if count >= 100000 then
sigfig = 3
end
-- Prepare to round to appropriate number of sigfigs
local f = math.floor(math.log10(count)) - sigfig + 1
-- Round and insert "apprxomimately" or "+" when appropriate
if (frame.args[2] == "yes") or (mw.ustring.sub(frame.args[1],-1) == "+") then
-- Round down
return_value = string.format("%s+", mw.getContentLanguage():formatNum(math.floor( (count / 10^(f)) ) * (10^(f))) )
else
-- Round to nearest
return_value = string.format("approximately %s", mw.getContentLanguage():formatNum(math.floor( (count / 10^(f)) + 0.5) * (10^(f))) )
end
-- Insert percent of pages
if frame.args["all-pages"] and frame.args["all-pages"] ~= "" then
local percent = math.floor( ( (count/frame:callParserFunction('NUMBEROFPAGES', 'R') ) * 100) + 0.5)
return_value = string.format("%s pages, or roughly %s%% of all", return_value, percent)
end
end
return return_value
end
function p.risk(frame)
local return_value = ""
if frame.args[1] == "risk" then
return_value = "risk"
else
local count = _fetch(frame)
if count and count >= 100000 then return_value = "risk" end
end
return return_value
end
function p.text(frame, count)
if count == nil then count = _fetch(frame) end
local return_value = {}
local title = mw.title.getCurrentTitle()
if title.subpageText == "doc" or title.subpageText == "sandbox" then
title = title.basePageTitle
end
local templatecount = string.format("https://tools.wmflabs.org/templatecount/index.php?lang=en&namespace=%s&name=%s",mw.title.getCurrentTitle().namespace,mw.uri.encode(title.text))
local used_on_text = string.format("'''This %s is used on [%s %s pages]'''",
(mw.title.getCurrentTitle().namespace == 828 and "Lua module" or "template"),
templatecount,
p.num(frame, count)
)
local sandbox_text = string.format("%s's [[%s/sandbox|/sandbox]] or [[%s/testcases|/testcases]] subpages%s ",
(mw.title.getCurrentTitle().namespace == 828 and "module" or "template"),
title.fullText, title.fullText,
(mw.title.getCurrentTitle().namespace == 828 and "." or ", or in your own [[Wikipedia:Subpages#How to create user subpages|user subpage]].")
)
if (frame.args[1] == "risk" or (count and count >= 100000) ) then
local info = ""
if frame.args["info"] and frame.args["info"] ~= "" then
info = "<br />" .. frame.args["info"]
end
sandbox_text = string.format(".%s<br /> To avoid major disruption and server load, any changes should be tested in the %sThe tested changes can be added to this page in a single edit. ",
info, sandbox_text
)
else
sandbox_text = string.format(" and changes may be widely noticed. Test changes in the %s",
sandbox_text
)
end
local discussion_text = "Consider discussing changes "
if frame.args["2"] and frame.args["2"] ~= "" and frame.args["2"] ~= "yes" then
discussion_text = string.format("%sat [[%s]]", discussion_text, frame.args["2"])
else
discussion_text = string.format("%son the [[%s|talk page]]", discussion_text, title.talkPageTitle.fullText )
end
return table.concat({used_on_text, sandbox_text, discussion_text, " before implementing them."})
end
function p.main(frame)
local count = _fetch(frame)
local return_value = ""
local image = "[[File:Ambox warning yellow.svg|40px|alt=Warning|link=]]"
local type_param = "style"
if (frame.args[1] == "risk" or (count and count >= 100000) ) then
image = "[[File:Ambox warning orange.svg|40px|alt=Warning|link=]]"
type_param = "content"
end
if frame.args["form"] == "editnotice" then
return_value = frame:expandTemplate{
title = 'editnotice',
args = {
["image"] = image,
["text"] = p.text(frame, count),
["expiry"] = (frame.args["expiry"] or "")
}
}
else
return_value = frame:expandTemplate{
title = 'ombox',
args = {
["type"] = type_param,
["image"] = image,
["text"] = p.text(frame, count),
["expiry"] = (frame.args["expiry"] or "")
}
}
end
return return_value
end
return p