Difference between revisions of "Module:Message box"
m (1 revision: Wikipedia Infobox) |
|||
Line 1: | Line 1: | ||
-- This is a meta-module for producing message box templates, including | -- This is a meta-module for producing message box templates, including | ||
-- {{mbox}}, {{ambox}}, {{imbox}}, {{tmbox}}, {{ombox}}, {{cmbox}} and {{fmbox}}. | -- {{mbox}}, {{ambox}}, {{imbox}}, {{tmbox}}, {{ombox}}, {{cmbox}} and {{fmbox}}. | ||
− | + | ||
-- Require necessary modules. | -- Require necessary modules. | ||
local getArgs = require('Module:Arguments').getArgs | local getArgs = require('Module:Arguments').getArgs | ||
Line 7: | Line 7: | ||
local categoryHandler = require('Module:Category handler').main | local categoryHandler = require('Module:Category handler').main | ||
local yesno = require('Module:Yesno') | local yesno = require('Module:Yesno') | ||
− | + | ||
-- Load the configuration page. | -- Load the configuration page. | ||
local cfgTables = mw.loadData('Module:Message box/configuration') | local cfgTables = mw.loadData('Module:Message box/configuration') | ||
− | + | ||
-- Get a language object for formatDate and ucfirst. | -- Get a language object for formatDate and ucfirst. | ||
local lang = mw.language.getContentLanguage() | local lang = mw.language.getContentLanguage() | ||
− | + | ||
-- Set aliases for often-used functions to reduce table lookups. | -- Set aliases for often-used functions to reduce table lookups. | ||
local format = mw.ustring.format | local format = mw.ustring.format | ||
Line 19: | Line 19: | ||
local tconcat = table.concat | local tconcat = table.concat | ||
local trim = mw.text.trim | local trim = mw.text.trim | ||
− | + | ||
-------------------------------------------------------------------------------- | -------------------------------------------------------------------------------- | ||
-- Helper functions | -- Helper functions | ||
-------------------------------------------------------------------------------- | -------------------------------------------------------------------------------- | ||
− | + | ||
local function getTitleObject(page, ...) | local function getTitleObject(page, ...) | ||
if type(page) == 'string' then | if type(page) == 'string' then | ||
Line 34: | Line 34: | ||
end | end | ||
end | end | ||
− | + | ||
local function union(t1, t2) | local function union(t1, t2) | ||
-- Returns the union of two arrays. | -- Returns the union of two arrays. | ||
Line 51: | Line 51: | ||
return ret | return ret | ||
end | end | ||
− | + | ||
local function getArgNums(args, prefix) | local function getArgNums(args, prefix) | ||
local nums = {} | local nums = {} | ||
Line 63: | Line 63: | ||
return nums | return nums | ||
end | end | ||
− | + | ||
-------------------------------------------------------------------------------- | -------------------------------------------------------------------------------- | ||
-- Box class definition | -- Box class definition | ||
-------------------------------------------------------------------------------- | -------------------------------------------------------------------------------- | ||
− | + | ||
local box = {} | local box = {} | ||
box.__index = box | box.__index = box | ||
− | + | ||
function box.new() | function box.new() | ||
local obj = {} | local obj = {} | ||
Line 76: | Line 76: | ||
return obj | return obj | ||
end | end | ||
− | + | ||
function box.getNamespaceId(ns) | function box.getNamespaceId(ns) | ||
if not ns then return end | if not ns then return end | ||
Line 90: | Line 90: | ||
end | end | ||
end | end | ||
− | + | ||
function box.getMboxType(nsid) | function box.getMboxType(nsid) | ||
-- Gets the mbox type from a namespace number. | -- Gets the mbox type from a namespace number. | ||
Line 108: | Line 108: | ||
end | end | ||
end | end | ||
− | + | ||
function box:addCat(ns, cat, sort) | function box:addCat(ns, cat, sort) | ||
if type(cat) ~= 'string' then return end | if type(cat) ~= 'string' then return end | ||
Line 134: | Line 134: | ||
end | end | ||
end | end | ||
− | + | ||
function box:addClass(class) | function box:addClass(class) | ||
if type(class) ~= 'string' then return end | if type(class) ~= 'string' then return end | ||
Line 140: | Line 140: | ||
tinsert(self.classes, class) | tinsert(self.classes, class) | ||
end | end | ||
− | + | ||
function box:addAttr(attr, val) | function box:addAttr(attr, val) | ||
if type(attr) ~= 'string' or type(val) ~= 'string' then return end | if type(attr) ~= 'string' or type(val) ~= 'string' then return end | ||
Line 146: | Line 146: | ||
tinsert(self.attrs, attr) | tinsert(self.attrs, attr) | ||
end | end | ||
− | + | ||
function box:setTitle(args) | function box:setTitle(args) | ||
-- Get the title object and the namespace. | -- Get the title object and the namespace. | ||
Line 154: | Line 154: | ||
self.nsid = box.getNamespaceId(self.demospace) or self.title.namespace | self.nsid = box.getNamespaceId(self.demospace) or self.title.namespace | ||
end | end | ||
− | + | ||
function box:getConfig(boxType) | function box:getConfig(boxType) | ||
-- Get the box config data from the data page. | -- Get the box config data from the data page. | ||
Line 175: | Line 175: | ||
return cfg | return cfg | ||
end | end | ||
− | + | ||
function box:removeBlankArgs(cfg, args) | function box:removeBlankArgs(cfg, args) | ||
-- Only allow blank arguments for the parameter names listed in | -- Only allow blank arguments for the parameter names listed in | ||
Line 190: | Line 190: | ||
return newArgs | return newArgs | ||
end | end | ||
− | + | ||
function box:setBoxParameters(cfg, args) | function box:setBoxParameters(cfg, args) | ||
-- Get type data. | -- Get type data. | ||
Line 203: | Line 203: | ||
self.typeClass = typeData.class | self.typeClass = typeData.class | ||
self.typeImage = typeData.image | self.typeImage = typeData.image | ||
− | + | ||
-- Find if the box has been wrongly substituted. | -- Find if the box has been wrongly substituted. | ||
if cfg.substCheck and args.subst == 'SUBST' then | if cfg.substCheck and args.subst == 'SUBST' then | ||
self.isSubstituted = true | self.isSubstituted = true | ||
end | end | ||
− | + | ||
-- Find whether we are using a small message box. | -- Find whether we are using a small message box. | ||
if cfg.allowSmall and ( | if cfg.allowSmall and ( | ||
Line 219: | Line 219: | ||
self.isSmall = false | self.isSmall = false | ||
end | end | ||
− | + | ||
-- Add attributes, classes and styles. | -- Add attributes, classes and styles. | ||
if cfg.allowId then | if cfg.allowId then | ||
Line 237: | Line 237: | ||
self.style = args.style | self.style = args.style | ||
self.attrs = args.attrs | self.attrs = args.attrs | ||
− | + | ||
-- Set text style. | -- Set text style. | ||
self.textstyle = args.textstyle | self.textstyle = args.textstyle | ||
− | + | ||
-- Find if we are on the template page or not. This functionality is only | -- Find if we are on the template page or not. This functionality is only | ||
-- used if useCollapsibleTextFields is set, or if both cfg.templateCategory | -- used if useCollapsibleTextFields is set, or if both cfg.templateCategory | ||
Line 262: | Line 262: | ||
or false | or false | ||
end | end | ||
− | + | ||
-- Process data for collapsible text fields. At the moment these are only | -- Process data for collapsible text fields. At the moment these are only | ||
-- used in {{ambox}}. | -- used in {{ambox}}. | ||
Line 286: | Line 286: | ||
self.issue = tconcat(issues, ' ') | self.issue = tconcat(issues, ' ') | ||
end | end | ||
− | + | ||
-- Get the self.talk value. | -- Get the self.talk value. | ||
local talk = args.talk | local talk = args.talk | ||
Line 335: | Line 335: | ||
end | end | ||
end | end | ||
− | + | ||
-- Get other values. | -- Get other values. | ||
self.fix = args.fix ~= '' and args.fix or nil | self.fix = args.fix ~= '' and args.fix or nil | ||
Line 349: | Line 349: | ||
self.info = args.info | self.info = args.info | ||
end | end | ||
− | + | ||
-- Set the non-collapsible text field. At the moment this is used by all box | -- Set the non-collapsible text field. At the moment this is used by all box | ||
-- types other than ambox, and also by ambox when small=yes. | -- types other than ambox, and also by ambox when small=yes. | ||
Line 357: | Line 357: | ||
self.text = args.text | self.text = args.text | ||
end | end | ||
− | + | ||
-- Set the below row. | -- Set the below row. | ||
self.below = cfg.below and args.below | self.below = cfg.below and args.below | ||
− | + | ||
-- General image settings. | -- General image settings. | ||
self.imageCellDiv = not self.isSmall and cfg.imageCellDiv and true or false | self.imageCellDiv = not self.isSmall and cfg.imageCellDiv and true or false | ||
Line 367: | Line 367: | ||
self.imageEmptyCellStyle = 'border:none;padding:0px;width:1px' | self.imageEmptyCellStyle = 'border:none;padding:0px;width:1px' | ||
end | end | ||
− | + | ||
-- Left image settings. | -- Left image settings. | ||
local imageLeft = self.isSmall and args.smallimage or args.image | local imageLeft = self.isSmall and args.smallimage or args.image | ||
Line 382: | Line 382: | ||
end | end | ||
end | end | ||
− | + | ||
-- Right image settings. | -- Right image settings. | ||
local imageRight = self.isSmall and args.smallimageright or args.imageright | local imageRight = self.isSmall and args.smallimageright or args.imageright | ||
Line 388: | Line 388: | ||
self.imageRight = imageRight | self.imageRight = imageRight | ||
end | end | ||
− | + | ||
-- Add mainspace categories. At the moment these are only used in {{ambox}}. | -- Add mainspace categories. At the moment these are only used in {{ambox}}. | ||
if cfg.allowMainspaceCategories then | if cfg.allowMainspaceCategories then | ||
Line 433: | Line 433: | ||
end | end | ||
end | end | ||
− | + | ||
-- Add template-namespace categories. | -- Add template-namespace categories. | ||
if cfg.templateCategory then | if cfg.templateCategory then | ||
Line 444: | Line 444: | ||
end | end | ||
end | end | ||
− | + | ||
-- Add template error category. | -- Add template error category. | ||
if cfg.templateErrorCategory then | if cfg.templateErrorCategory then | ||
Line 470: | Line 470: | ||
self:addCat('template', templateCat, templateSort) | self:addCat('template', templateCat, templateSort) | ||
end | end | ||
− | + | ||
-- Categories for all namespaces. | -- Categories for all namespaces. | ||
if self.invalidTypeError then | if self.invalidTypeError then | ||
Line 479: | Line 479: | ||
self:addCat('all', 'Pages with incorrectly substituted templates') | self:addCat('all', 'Pages with incorrectly substituted templates') | ||
end | end | ||
− | + | ||
-- Convert category tables to strings and pass them through | -- Convert category tables to strings and pass them through | ||
-- [[Module:Category handler]]. | -- [[Module:Category handler]]. | ||
Line 491: | Line 491: | ||
} | } | ||
end | end | ||
− | + | ||
function box:export() | function box:export() | ||
local root = htmlBuilder.create() | local root = htmlBuilder.create() | ||
− | + | ||
-- Add the subst check error. | -- Add the subst check error. | ||
if self.isSubstituted and self.name then | if self.isSubstituted and self.name then | ||
Line 505: | Line 505: | ||
)) | )) | ||
end | end | ||
− | + | ||
-- Create the box table. | -- Create the box table. | ||
local boxTable = root.tag('table') | local boxTable = root.tag('table') | ||
Line 521: | Line 521: | ||
.attr(attr, val) | .attr(attr, val) | ||
end | end | ||
− | + | ||
-- Add the left-hand image. | -- Add the left-hand image. | ||
local row = boxTable.tag('tr') | local row = boxTable.tag('tr') | ||
Line 544: | Line 544: | ||
.cssText(self.imageEmptyCellStyle) | .cssText(self.imageEmptyCellStyle) | ||
end | end | ||
− | + | ||
-- Add the text. | -- Add the text. | ||
local textCell = row.tag('td').addClass('mbox-text') | local textCell = row.tag('td').addClass('mbox-text') | ||
Line 577: | Line 577: | ||
.wikitext(self.text) | .wikitext(self.text) | ||
end | end | ||
− | + | ||
-- Add the right-hand image. | -- Add the right-hand image. | ||
if self.imageRight then | if self.imageRight then | ||
Line 589: | Line 589: | ||
.wikitext(self.imageRight) | .wikitext(self.imageRight) | ||
end | end | ||
− | + | ||
-- Add the below row. | -- Add the below row. | ||
if self.below then | if self.below then | ||
Line 599: | Line 599: | ||
.wikitext(self.below) | .wikitext(self.below) | ||
end | end | ||
− | + | ||
-- Add error message for invalid type parameters. | -- Add error message for invalid type parameters. | ||
if self.invalidTypeError then | if self.invalidTypeError then | ||
Line 610: | Line 610: | ||
)) | )) | ||
end | end | ||
− | + | ||
-- Add categories. | -- Add categories. | ||
root | root | ||
.wikitext(self.categories) | .wikitext(self.categories) | ||
− | + | ||
return tostring(root) | return tostring(root) | ||
end | end | ||
− | + | ||
local function main(boxType, args) | local function main(boxType, args) | ||
local outputBox = box.new() | local outputBox = box.new() | ||
Line 626: | Line 626: | ||
return outputBox:export() | return outputBox:export() | ||
end | end | ||
− | + | ||
local function makeWrapper(boxType) | local function makeWrapper(boxType) | ||
return function (frame) | return function (frame) | ||
Line 633: | Line 633: | ||
end | end | ||
end | end | ||
− | + | ||
local p = { | local p = { | ||
main = main, | main = main, | ||
mbox = makeWrapper('mbox') | mbox = makeWrapper('mbox') | ||
} | } | ||
− | + | ||
for boxType in pairs(cfgTables) do | for boxType in pairs(cfgTables) do | ||
p[boxType] = makeWrapper(boxType) | p[boxType] = makeWrapper(boxType) | ||
end | end | ||
− | + | ||
return p | return p |
Revision as of 17:09, 24 November 2014
This is a meta-module that implements the message box templates {{mbox}}, {{ambox}}, {{cmbox}}, {{fmbox}}, {{imbox}}, {{ombox}}, and {{tmbox}}. It is intended to be used from Lua modules, and should not be used directly from wiki pages. If you want to use this module's functionality from a wiki page, please use the individual message box templates instead.
Usage
To use this module from another Lua module, first you need to load it.
local messageBox = require('Module:Message box')
To create a message box, use the main
function. It takes two parameters: the first is the box type (as a string), and the second is a table containing the message box parameters.
local box = messageBox.main( boxType, {
param1 = param1,
param2 = param2,
-- More parameters...
})
There are seven available box types:
Box type | Template | Purpose |
---|---|---|
mbox |
{{mbox}} | For message boxes to be used in multiple namespaces |
ambox |
{{ambox}} | For article message boxes |
cmbox |
{{cmbox}} | For category message boxes |
fmbox |
{{fmbox}} | For interface message boxes |
imbox |
{{imbox}} | For file namespace message boxes |
tmbox |
{{tmbox}} | For talk page message boxes |
ombox |
{{ombox}} | For message boxes in other namespaces |
See the template page of each box type for the available parameters.
Usage from #invoke
As well as the main
function, this module has separate functions for each box type. They are accessed using the code {{#invoke:Message box|mbox|...}}
, {{#invoke:Message box|ambox|...}}
, etc. These will work when called from other modules, but they access code used to process arguments passed from #invoke, and so calling them will be less efficient than calling main
.
Technical details
The module uses the same basic code for each of the templates listed above; the differences between each of them are configured using the data at Module:Message box/configuration. Here are the various configuration options and what they mean:
types
- a table containing data used by the type parameter of the message box. The table keys are the values that can be passed to the type parameter, and the table values are tables containing the class and the image used by that type.default
- the type to use if no value was passed to the type parameter, or if an invalid value was specified.showInvalidTypeError
- whether to show an error if the value passed to the type parameter was invalid.allowBlankParams
- usually blank values are stripped from parameters passed to the module. However, whitespace is preserved for the parameters included in the allowBlankParams table.allowSmall
- whether a small version of the message box can be produced with "small=yes".smallParam
- a custom name for the small parameter. For example, if set to "left" you can produce a small message box using "small=left".smallClass
- the class to use for small message boxes.substCheck
- whether to perform a subst check or not.classes
- an array of classes to use with the message box.usePlainlinksParam
- whether to allow "plainlinks=no" to turn off the plainlinks class.imageEmptyCell
- whether to use an empty<td>...</td>
cell if there is no image set. This is used to preserve spacing for message boxes with a width of less than 100% of the screen.imageEmptyCellStyle
- whether empty image cells should be styled.imageCheckBlank
- whether "image=blank" results in no image being displayed.imageSmallSize
- usually, images used in small message boxes are set to 30x30px. This sets a custom size.imageCellDiv
- whether to enclose the image in a div enforcing a maximum image size.useCollapsibleTextFields
- whether to use text fields that can be collapsed, i.e. "issue", "fix", "talk", etc. Currently only used in ambox.imageRightNone
- whether imageright=none results in no image being displayed on the right-hand side of the message box.sectionDefault
- the default name for the "section" parameter. Depends onuseCollapsibleTextFields
.allowMainspaceCategories
- allow categorisation in the main namespace.templateCategory
- the name of a category to be placed on the template page.templateCategoryRequireName
- whether thename
parameter is required to display the template category.templateErrorCategory
- the name of the error category to be used on the template page.templateErrorParamsToCheck
- an array of parameter names to check. If any are absent, thetemplateErrorCategory
is applied to the template page.
-- This is a meta-module for producing message box templates, including
-- {{mbox}}, {{ambox}}, {{imbox}}, {{tmbox}}, {{ombox}}, {{cmbox}} and {{fmbox}}.
-- Require necessary modules.
local getArgs = require('Module:Arguments').getArgs
local htmlBuilder = require('Module:HtmlBuilder')
local categoryHandler = require('Module:Category handler').main
local yesno = require('Module:Yesno')
-- Load the configuration page.
local cfgTables = mw.loadData('Module:Message box/configuration')
-- Get a language object for formatDate and ucfirst.
local lang = mw.language.getContentLanguage()
-- Set aliases for often-used functions to reduce table lookups.
local format = mw.ustring.format
local tinsert = table.insert
local tconcat = table.concat
local trim = mw.text.trim
--------------------------------------------------------------------------------
-- Helper functions
--------------------------------------------------------------------------------
local function getTitleObject(page, ...)
if type(page) == 'string' then
-- Get the title object, passing the function through pcall
-- in case we are over the expensive function count limit.
local success, title = pcall(mw.title.new, page, ...)
if success then
return title
end
end
end
local function union(t1, t2)
-- Returns the union of two arrays.
local vals = {}
for i, v in ipairs(t1) do
vals[v] = true
end
for i, v in ipairs(t2) do
vals[v] = true
end
local ret = {}
for k in pairs(vals) do
tinsert(ret, k)
end
table.sort(ret)
return ret
end
local function getArgNums(args, prefix)
local nums = {}
for k, v in pairs(args) do
local num = mw.ustring.match(tostring(k), '^' .. prefix .. '([1-9]%d*)$')
if num then
tinsert(nums, tonumber(num))
end
end
table.sort(nums)
return nums
end
--------------------------------------------------------------------------------
-- Box class definition
--------------------------------------------------------------------------------
local box = {}
box.__index = box
function box.new()
local obj = {}
setmetatable(obj, box)
return obj
end
function box.getNamespaceId(ns)
if not ns then return end
if type(ns) == 'string' then
ns = lang:ucfirst(mw.ustring.lower(ns))
if ns == 'Main' then
ns = 0
end
end
local nsTable = mw.site.namespaces[ns]
if nsTable then
return nsTable.id
end
end
function box.getMboxType(nsid)
-- Gets the mbox type from a namespace number.
if nsid == 0 then
return 'ambox' -- main namespace
elseif nsid == 6 then
return 'imbox' -- file namespace
elseif nsid == 14 then
return 'cmbox' -- category namespace
else
local nsTable = mw.site.namespaces[nsid]
if nsTable and nsTable.isTalk then
return 'tmbox' -- any talk namespace
else
return 'ombox' -- other namespaces or invalid input
end
end
end
function box:addCat(ns, cat, sort)
if type(cat) ~= 'string' then return end
local nsVals = {'main', 'template', 'all'}
local tname
for i, val in ipairs(nsVals) do
if ns == val then
tname = ns .. 'Cats'
end
end
if not tname then
for i, val in ipairs(nsVals) do
nsVals[i] = format('"%s"', val)
end
error(
'invalid ns parameter passed to box:addCat; valid values are '
.. mw.text.listToText(nsVals, nil, ' or ')
)
end
self[tname] = self[tname] or {}
if type(sort) == 'string' then
tinsert(self[tname], format('[[Category:%s|%s]]', cat, sort))
else
tinsert(self[tname], format('[[Category:%s]]', cat))
end
end
function box:addClass(class)
if type(class) ~= 'string' then return end
self.classes = self.classes or {}
tinsert(self.classes, class)
end
function box:addAttr(attr, val)
if type(attr) ~= 'string' or type(val) ~= 'string' then return end
self.attrs = self.attrs or {}
tinsert(self.attrs, attr)
end
function box:setTitle(args)
-- Get the title object and the namespace.
self.pageTitle = getTitleObject(args.page ~= '' and args.page)
self.title = self.pageTitle or mw.title.getCurrentTitle()
self.demospace = args.demospace ~= '' and args.demospace or nil
self.nsid = box.getNamespaceId(self.demospace) or self.title.namespace
end
function box:getConfig(boxType)
-- Get the box config data from the data page.
if boxType == 'mbox' then
boxType = box.getMboxType(self.nsid)
end
local cfg = cfgTables[boxType]
if not cfg then
local boxTypes = {}
for k, v in pairs(dataTables) do
tinsert(boxTypes, format('"%s"', k))
end
tinsert(boxTypes, '"mbox"')
error(format(
'invalid message box type "%s"; valid types are %s',
tostring(boxType),
mw.text.listToText(boxTypes)
), 2)
end
return cfg
end
function box:removeBlankArgs(cfg, args)
-- Only allow blank arguments for the parameter names listed in
-- cfg.allowBlankParams.
local newArgs = {}
for k, v in pairs(args) do
if v ~= '' then
newArgs[k] = v
end
end
for i, param in ipairs(cfg.allowBlankParams or {}) do
newArgs[param] = args[param]
end
return newArgs
end
function box:setBoxParameters(cfg, args)
-- Get type data.
self.type = args.type
local typeData = cfg.types[self.type]
self.invalidTypeError = cfg.showInvalidTypeError
and self.type
and not typeData
and true
or false
typeData = typeData or cfg.types[cfg.default]
self.typeClass = typeData.class
self.typeImage = typeData.image
-- Find if the box has been wrongly substituted.
if cfg.substCheck and args.subst == 'SUBST' then
self.isSubstituted = true
end
-- Find whether we are using a small message box.
if cfg.allowSmall and (
cfg.smallParam and args.small == cfg.smallParam
or not cfg.smallParam and yesno(args.small)
)
then
self.isSmall = true
else
self.isSmall = false
end
-- Add attributes, classes and styles.
if cfg.allowId then
self.id = args.id
end
self:addClass(
cfg.usePlainlinksParam and yesno(args.plainlinks or true) and 'plainlinks'
)
for _, class in ipairs(cfg.classes or {}) do
self:addClass(class)
end
if self.isSmall then
self:addClass(cfg.smallClass or 'mbox-small')
end
self:addClass(self.typeClass)
self:addClass(args.class)
self.style = args.style
self.attrs = args.attrs
-- Set text style.
self.textstyle = args.textstyle
-- Find if we are on the template page or not. This functionality is only
-- used if useCollapsibleTextFields is set, or if both cfg.templateCategory
-- and cfg.templateCategoryRequireName are set.
self.useCollapsibleTextFields = cfg.useCollapsibleTextFields
if self.useCollapsibleTextFields
or cfg.templateCategory
and cfg.templateCategoryRequireName
then
self.name = args.name
if self.name then
local templateName = mw.ustring.match(
self.name,
'^[tT][eE][mM][pP][lL][aA][tT][eE][%s_]*:[%s_]*(.*)$'
) or self.name
templateName = 'Template:' .. templateName
self.templateTitle = getTitleObject(templateName)
end
self.isTemplatePage = self.templateTitle
and mw.title.equals(self.title, self.templateTitle)
or false
end
-- Process data for collapsible text fields. At the moment these are only
-- used in {{ambox}}.
if self.useCollapsibleTextFields then
-- Get the self.issue value.
if self.isSmall and args.smalltext then
self.issue = args.smalltext
else
local sect
if args.sect == '' then
sect = 'This ' .. (cfg.sectionDefault or 'page')
elseif type(args.sect) == 'string' then
sect = 'This ' .. args.sect
end
local issue = args.issue
issue = type(issue) == 'string' and issue ~= '' and issue or nil
local text = args.text
text = type(text) == 'string' and text or nil
local issues = {}
tinsert(issues, sect)
tinsert(issues, issue)
tinsert(issues, text)
self.issue = tconcat(issues, ' ')
end
-- Get the self.talk value.
local talk = args.talk
-- Show talk links on the template page or template subpages if the talk
-- parameter is blank.
if talk == ''
and self.templateTitle
and (
mw.title.equals(self.templateTitle, self.title)
or self.title:isSubpageOf(self.templateTitle)
)
then
talk = '#'
elseif talk == '' then
talk = nil
end
if talk then
-- If the talk value is a talk page, make a link to that page. Else
-- assume that it's a section heading, and make a link to the talk
-- page of the current page with that section heading.
local talkTitle = getTitleObject(talk)
local talkArgIsTalkPage = true
if not talkTitle or not talkTitle.isTalkPage then
talkArgIsTalkPage = false
talkTitle = getTitleObject(
self.title.text,
mw.site.namespaces[self.title.namespace].talk.id
)
end
if talkTitle and talkTitle.exists then
local talkText = 'Relevant discussion may be found on'
if talkArgIsTalkPage then
talkText = format(
'%s [[%s|%s]].',
talkText,
talk,
talkTitle.prefixedText
)
else
talkText = format(
'%s the [[%s#%s|talk page]].',
talkText,
talkTitle.prefixedText,
talk
)
end
self.talk = talkText
end
end
-- Get other values.
self.fix = args.fix ~= '' and args.fix or nil
local date
if args.date and args.date ~= '' then
date = args.date
elseif args.date == '' and self.isTemplatePage then
date = lang:formatDate('F Y')
end
if date then
self.date = format(" <small>''(%s)''</small>", date)
end
self.info = args.info
end
-- Set the non-collapsible text field. At the moment this is used by all box
-- types other than ambox, and also by ambox when small=yes.
if self.isSmall then
self.text = args.smalltext or args.text
else
self.text = args.text
end
-- Set the below row.
self.below = cfg.below and args.below
-- General image settings.
self.imageCellDiv = not self.isSmall and cfg.imageCellDiv and true or false
self.imageEmptyCell = cfg.imageEmptyCell
if cfg.imageEmptyCellStyle then
self.imageEmptyCellStyle = 'border:none;padding:0px;width:1px'
end
-- Left image settings.
local imageLeft = self.isSmall and args.smallimage or args.image
if cfg.imageCheckBlank and imageLeft ~= 'blank' and imageLeft ~= 'none'
or not cfg.imageCheckBlank and imageLeft ~= 'none'
then
self.imageLeft = imageLeft
if not imageLeft then
local imageSize = self.isSmall
and (cfg.imageSmallSize or '30x30px')
or '40x40px'
self.imageLeft = format('[[File:%s|%s|link=|alt=]]', self.typeImage
or 'Imbox notice.png', imageSize)
end
end
-- Right image settings.
local imageRight = self.isSmall and args.smallimageright or args.imageright
if not (cfg.imageRightNone and imageRight == 'none') then
self.imageRight = imageRight
end
-- Add mainspace categories. At the moment these are only used in {{ambox}}.
if cfg.allowMainspaceCategories then
if args.cat then
args.cat1 = args.cat
end
self.catNums = getArgNums(args, 'cat')
if args.category then
args.category1 = args.category
end
self.categoryNums = getArgNums(args, 'category')
if args.all then
args.all1 = args.all
end
self.allNums = getArgNums(args, 'all')
self.categoryParamNums = union(self.catNums, self.categoryNums)
self.categoryParamNums = union(self.categoryParamNums, self.allNums)
-- The following is roughly equivalent to the old {{Ambox/category}}.
local date = args.date
date = type(date) == 'string' and date
local preposition = 'from'
for _, num in ipairs(self.categoryParamNums) do
local mainCat = args['cat' .. tostring(num)]
or args['category' .. tostring(num)]
local allCat = args['all' .. tostring(num)]
mainCat = type(mainCat) == 'string' and mainCat
allCat = type(allCat) == 'string' and allCat
if mainCat and date and date ~= '' then
local catTitle = format('%s %s %s', mainCat, preposition, date)
self:addCat('main', catTitle)
catTitle = getTitleObject('Category:' .. catTitle)
if not catTitle or not catTitle.exists then
self:addCat(
'main',
'Articles with invalid date parameter in template'
)
end
elseif mainCat and (not date or date == '') then
self:addCat('main', mainCat)
end
if allCat then
self:addCat('main', allCat)
end
end
end
-- Add template-namespace categories.
if cfg.templateCategory then
if cfg.templateCategoryRequireName then
if self.isTemplatePage then
self:addCat('template', cfg.templateCategory)
end
elseif not self.title.isSubpage then
self:addCat('template', cfg.templateCategory)
end
end
-- Add template error category.
if cfg.templateErrorCategory then
local templateErrorCategory = cfg.templateErrorCategory
local templateCat, templateSort
if not self.name and not self.title.isSubpage then
templateCat = templateErrorCategory
elseif self.isTemplatePage then
local paramsToCheck = cfg.templateErrorParamsToCheck or {}
local count = 0
for i, param in ipairs(paramsToCheck) do
if not args[param] then
count = count + 1
end
end
if count > 0 then
templateCat = templateErrorCategory
templateSort = tostring(count)
end
if self.categoryNums and #self.categoryNums > 0 then
templateCat = templateErrorCategory
templateSort = 'C'
end
end
self:addCat('template', templateCat, templateSort)
end
-- Categories for all namespaces.
if self.invalidTypeError then
local allSort = (self.nsid == 0 and 'Main:' or '') .. self.title.prefixedText
self:addCat('all', 'Wikipedia message box parameter needs fixing', allSort)
end
if self.isSubstituted then
self:addCat('all', 'Pages with incorrectly substituted templates')
end
-- Convert category tables to strings and pass them through
-- [[Module:Category handler]].
self.categories = categoryHandler{
main = tconcat(self.mainCats or {}),
template = tconcat(self.templateCats or {}),
all = tconcat(self.allCats or {}),
nocat = args.nocat,
demospace = self.demospace,
page = self.pageTitle and self.pageTitle.prefixedText or nil
}
end
function box:export()
local root = htmlBuilder.create()
-- Add the subst check error.
if self.isSubstituted and self.name then
root
.tag('b')
.addClass('error')
.wikitext(format(
'Template <code>%s[[Template:%s|%s]]%s</code> has been incorrectly substituted.',
mw.text.nowiki('{{'), self.name, self.name, mw.text.nowiki('}}')
))
end
-- Create the box table.
local boxTable = root.tag('table')
boxTable
.attr('id', self.id)
for i, class in ipairs(self.classes or {}) do
boxTable
.addClass(class)
end
boxTable
.cssText(self.style)
.attr('role', 'presentation')
for attr, val in pairs(self.attrs or {}) do
boxTable
.attr(attr, val)
end
-- Add the left-hand image.
local row = boxTable.tag('tr')
if self.imageLeft then
local imageLeftCell = row.tag('td').addClass('mbox-image')
if self.imageCellDiv then
-- If we are using a div, redefine imageLeftCell so that the image
-- is inside it. Divs use style="width: 52px;", which limits the
-- image width to 52px. If any images in a div are wider than that,
-- they may overlap with the text or cause other display problems.
imageLeftCell = imageLeftCell.tag('div').css('width', '52px')
end
imageLeftCell
.wikitext(self.imageLeft)
elseif self.imageEmptyCell then
-- Some message boxes define an empty cell if no image is specified, and
-- some don't. The old template code in templates where empty cells are
-- specified gives the following hint: "No image. Cell with some width
-- or padding necessary for text cell to have 100% width."
row.tag('td')
.addClass('mbox-empty-cell')
.cssText(self.imageEmptyCellStyle)
end
-- Add the text.
local textCell = row.tag('td').addClass('mbox-text')
if self.useCollapsibleTextFields then
-- The message box uses advanced text parameters that allow things to be
-- collapsible. At the moment, only ambox uses this.
textCell
.cssText(self.textstyle)
local textCellSpan = textCell.tag('span')
textCellSpan
.addClass('mbox-text-span')
.wikitext(self.issue)
if not self.isSmall then
textCellSpan
.tag('span')
.addClass('hide-when-compact')
.wikitext(self.talk and ' ' .. self.talk)
.wikitext(self.fix and ' ' .. self.fix)
end
textCellSpan
.wikitext(self.date and ' ' .. self.date)
if not self.isSmall then
textCellSpan
.tag('span')
.addClass('hide-when-compact')
.wikitext(self.info and ' ' .. self.info)
end
else
-- Default text formatting - anything goes.
textCell
.cssText(self.textstyle)
.wikitext(self.text)
end
-- Add the right-hand image.
if self.imageRight then
local imageRightCell = row.tag('td').addClass('mbox-imageright')
if self.imageCellDiv then
-- If we are using a div, redefine imageRightCell so that the image
-- is inside it.
imageRightCell = imageRightCell.tag('div').css('width', '52px')
end
imageRightCell
.wikitext(self.imageRight)
end
-- Add the below row.
if self.below then
boxTable.tag('tr')
.tag('td')
.attr('colspan', self.imageRight and '3' or '2')
.addClass('mbox-text')
.cssText(self.textstyle)
.wikitext(self.below)
end
-- Add error message for invalid type parameters.
if self.invalidTypeError then
root
.tag('div')
.css('text-align', 'center')
.wikitext(format(
'This message box is using an invalid "type=%s" parameter and needs fixing.',
self.type or ''
))
end
-- Add categories.
root
.wikitext(self.categories)
return tostring(root)
end
local function main(boxType, args)
local outputBox = box.new()
outputBox:setTitle(args)
local cfg = outputBox:getConfig(boxType)
args = outputBox:removeBlankArgs(cfg, args)
outputBox:setBoxParameters(cfg, args)
return outputBox:export()
end
local function makeWrapper(boxType)
return function (frame)
local args = getArgs(frame, {trim = false, removeBlanks = false})
return main(boxType, args)
end
end
local p = {
main = main,
mbox = makeWrapper('mbox')
}
for boxType in pairs(cfgTables) do
p[boxType] = makeWrapper(boxType)
end
return p