Difference between revisions of "Olympus OLS 4000 LEXT"

From LNF Wiki
Jump to navigation Jump to search
Line 16: Line 16:
 
|processes =
 
|processes =
 
|maintenance =  
 
|maintenance =  
 +
}}
 
{{warning|This page has not been released yet.}}
 
{{warning|This page has not been released yet.}}
  

Revision as of 10:11, 28 June 2017

Olympus OLS 4000 LEXT
82041.jpg
Olympus LEXT Laser Confocal Microscope
Equipment Details
Technology Metrology
Materials Restriction Metals
Material Processed no restrictions
Sample Size 6"x6" and 1 kg in weight
Equipment Manual
Overview System Overview[Olympus OLS 4000 LEXT#Material_Restrictions|Metals]]
Operating Procedure SOP


Warning Warning: This page has not been released yet.

The Olympus OLS 4000 LEXT is a laser confocal microscope that can take high resolution 3D images by acquiring successive images of the sample between two heights. It then recombines the laser acquired images and the color images to produce a 3D projection that can be measured. It can measure dimensions, roughness, area, volumes, etc. Its specially developed lenses produce high quality images of the sample. The z axis resolution is 10 nm and the x-y resolution is 120 nm.

Announcements

  • Update this with announcements as necessary

Capabilities

  • displays 3D images of the sample
  • z minimum resolution: 10 nm
  • x-y minimum resolution: 120 nm
  • measure surface roughness
  • measure line roughness
  • profile measurement
  • step measurement
  • measure geometry: angles, distance, areas
  • Area/Volume
  • confocal 2D images
  • laser confocal images
  • color confocal images
  • Differential interference Contrast (DIC)
  • film thickness
  • particle count
  • filter options help correct for noise, surface tilt, surface curvature or roughness
  • intensity data exported in .cvs file format
  • data can be saved in Excel file

System overview

Hardware details

  • 5X, 10X, 20X, 50X, 100X confocal objectives
  • 405 nm laser: photomultiplier detector
  • color image: white LED, 2-megapixel CCD detector
  • stage max weight: 1kg
  • stage travel 4"x 4"
  • Magnification range 108X - 17280X
  • DIC polarizer
  • Coarse stage adjustment allows examination of tall (10 cm ) samples

Substrate requirements

  • max sample diameter 6"
  • maximum sample thickness 10 cm
  • maximum sample weight 1 kg
  • small samples should be placed on a glass slide

Material restrictions

This microscope can be used with any material as long as it weighs less than 1.5 kg and fits comfortably under the lenses.

The Olympus OLS 4000 LEXT is designated as a Metals class tool. Below is a list of approved materials for the tool. Approved means the material is allowed in the tool under normal circumstances. If a material is not listed, please create a helpdesk ticket or email info@lnf.umich.edu for any material requests or questions.



If you are curious if your material can be processed in this tool, please contact the tool engineers via the helpdesk ticket system.

Standard operating procedure

Widget text will go here.

Checkout procedure

  1. Read through this page and the Standard Operating Procedure above.
  2. Create a Helpdesk Ticket requesting training.
  3. A tool engineer will schedule a time for initial training.
  4. Practice with your mentor or another authorized user until you are comfortable with tool operation.
  5. Schedule a checkout session with a tool engineer via the Helpdesk ticket system. If this checkout is successful, the engineer will authorize you on the tool.

Maintenance

Maintenance for this tool is done regularly using height standards.