In order to image and measure objects in the micron range it is necessary the use of a microscope. Microscope technology has advanced tremendously with the | In order to image and measure objects in the micron range it is necessary the use of a microscope. Microscope technology has advanced tremendously with the | ||
+ | |||
+ | ==Equipment== | ||
+ | |||
+ | [[Olympus BX 51 Fluorescent Microscope]]<br /> | ||
+ | [[Olympus IR Microscope]]<br /> | ||
+ | [[Nikon Eclipse LV150]]<br /> | ||
+ | [[Nikon MM-40]]<br /> | ||
+ | [[Nikon AZ100 Multi Zoom]] | ||
==Technologies== | ==Technologies== | ||
Line 52: | Line 60: | ||
==Applications== | ==Applications== | ||
Cell biology, microfabrication, geology, crystallography, etc. | Cell biology, microfabrication, geology, crystallography, etc. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==See also== | ==See also== | ||
Line 69: | Line 69: | ||
==Further reading== | ==Further reading== | ||
+ | *[http://lnf-wiki.eecs.umich.edu/wiki/User_Resources#LNF_Tech_Talks_.28technology_seminar_series.29 LNF Tech Talk for Metrology] | ||
* Other stuff, e.g. technology workshop slides | * Other stuff, e.g. technology workshop slides | ||
* External links (can be in another section below, if appropriate) | * External links (can be in another section below, if appropriate) |
Latest revision as of 10:13, 31 March 2020
Optical microscopy | |
---|---|
Technology Details | |
Other Names | Epi-fluorescence |
Technology | Metrology |
Equipment | Olympus BX51, Nikon Eclipse LV150, Nikon MM-40, Nikon AZ100 Multi zoom, |
Materials | wafers, devices, cells, materials, |
In order to image and measure objects in the micron range it is necessary the use of a microscope. Microscope technology has advanced tremendously with the
Contents
Equipment
Olympus BX 51 Fluorescent Microscope
Olympus IR Microscope
Nikon Eclipse LV150
Nikon MM-40
Nikon AZ100 Multi Zoom
Technologies
Optical Microscopy
The details of optical microscopy can be found in the well known work by Davidson and Abramowitz[1][2] as well as in Olympus[3] and Nikon Microscopy U[4].
The basics parts of a Microscope are illustrated in the figure below:

These days microscopes are equipped with more and more advanced CCD digital cameras, which has revolutionized the image caption, interpretation and manipulation. Also, improved designed objective lenses, new light sources, and motorized stages have taken digital microscopy to levels of image quality not found even 10 years ago. Still, microscope optics physics is the same, so the same basic elements have to be considered when choosing the right microscopy for the task at hand[6]
- Light Source
- Condenser
- Objective
- Filters
- Eye pieces
- Stage
- Stand
Fluorescent Microscopy
Describe the technology, particularly including why you might use it over another within the same group.
Infrared Microscopy
Here's another technology in that group.
Figures of Merit
- Resolution
- Depth of Field
- Image mode
- Magnification
- Sharpness
- Numerical Aperture
- Contrast
- Light source
Applications
Cell biology, microfabrication, geology, crystallography, etc.
See also
[[1]]
References
- ↑ https://micro.magnet.fsu.edu/primer/pdfs/microscopy.pdf
- ↑ http://ac.els-cdn.com/S0091679X06810010/1-s2.0-S0091679X06810010-main.pdf?_tid=645621dc-d990-11e5-8b97-00000aacb35e&acdnat=1456165168_cf87db97d04aaf4f8cc6ca3efbceafab
- ↑ http://olympus.magnet.fsu.edu/
- ↑ http://www.microscopyu.com/tutorials/
- ↑ http://www.microscopyu.com/tutorials
- ↑ http://ac.els-cdn.com/B0123694019005799/3-s2.0-B0123694019005799-main.pdf?_tid=08496042-d991-11e5-9d1b-00000aacb362&acdnat=1456165443_eb4672f672413c71c55c3ccdb217abe3
Further reading
- LNF Tech Talk for Metrology
- Other stuff, e.g. technology workshop slides
- External links (can be in another section below, if appropriate)