Authored By | Brian Vanderelzen |
The LNF Oxynitride LF is a legacy recipe on the STS Pegasus 4 and 6 that may be used to etch silicon dioxide and silicon nitride. Because the tool is not designed for this process, it also etches silicon and photoresist at a similar rate. It is primarily useful for native oxide removal prior to a deep Si etch. For oxide film etching, such as preparing an etch mask, the STS Glass Etcher and P5000 RIE have far superior performance and are strongly recommended. It is not actively supported by the LNF.
Procedure
Follow the SOP outlined on the tool page. Run LNF Oxynitride LF for up to 20 minutes with the 1 minute automated clean recipe, longer etches should be run with the 3 minute automated clean recipe.
Parameters
Parameter | Units | Setpoint |
---|---|---|
ICP Power | W | ? |
Bias Power | W | 100? |
Bias Pulsing | Hz | 40 Hz - 80% |
Pressure | mTorr | 10? |
C4F8 Flow | sccm | ? |
SF6 Flow | sccm | ? |
Ar Flow | sccm | ? |
Capabilities
Etch rate
Material | Etch Rate | Uniformity | Profile |
---|---|---|---|
Silicon dioxide | 1090 Å/min | 5.1% | ? |
Silicon nitride | ? | ? | ? |
Silicon | ? | ? | ? |
SPR 220 | 1520 Å/min | 5.9% | ? |
Process Report
Widget text will go here.
Limitations
This process is not recommended for most etch processes. There are other RIE tools in the lab with much better performance for oxide and nitride etching with higher selectivity to silicon and photoresist. Please create a helpdesk ticket or email info@lnf.umich.edu if you have further questions.