Difference between revisions of "STS Pegasus 4/Processes/LNF Switched Poly"

From LNF Wiki
Jump to navigation Jump to search
(Created page with "<!-- Make sure to add any other relevant categories --> {{#ifeq: {{NAMESPACE}} | Template | | Category:Processes}} {{warning|This page has not been released yet.}} {{Infob...")
 
 
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
<!-- Make sure to add any other relevant categories -->
+
<!-- Make sure to add any other relevant categories
{{#ifeq: {{NAMESPACE}} | Template | | [[Category:Processes]]}}
+
-->{{#ifeq: {{NAMESPACE}} | Template | | [[Category:Processes]]}}{{Infobox process
{{warning|This page has not been released yet.}}
+
|image      = STS Pegasus_4_Switched_Poly_1_um.jpg
{{Infobox process
 
|image      =  
 
 
|caption    =
 
|caption    =
 
|technology = RIE
 
|technology = RIE
 
|material  = [[Silicon]]
 
|material  = [[Silicon]]
|mask      = not typical
+
|mask      = [[Photoresist|PR]], [[Silicon dioxide|SiO<sub>2</sub>]]
|chemicals  = [[Photoresist|PR]], [[Silicon dioxide|SiO<sub>2</sub>]]
+
|chemicals  =
 
|gases      = [[SF6|SF<sub>6</sub>]], [[C4F8|C<sub>4</sub>F<sub>8</sub>]], [[O2|O<sub>2</sub>]]
 
|gases      = [[SF6|SF<sub>6</sub>]], [[C4F8|C<sub>4</sub>F<sub>8</sub>]], [[O2|O<sub>2</sub>]]
 
|created    =  
 
|created    =  
Line 15: Line 13:
 
}}
 
}}
 
'''{{SUBPAGENAME}}''' is a Bosch-style switched process intended for shallow silicon and thin film poly- and amorphous silicon etches.
 
'''{{SUBPAGENAME}}''' is a Bosch-style switched process intended for shallow silicon and thin film poly- and amorphous silicon etches.
 +
 +
{{note|The STS Pegasus is not designed for polysilicon etching. There are other tools at the LNF specifically designed for this, including the [[LAM 9400]] and the [[P5000 RIE]]. Please make a helpdesk ticket if you need assistance determining the correct tool or recipe for your process.|reminder}}
  
 
==Procedure==
 
==Procedure==
Line 27: Line 27:
 
|-
 
|-
 
| ICP Power
 
| ICP Power
| ? W
+
| 800 W
| ? W
+
| 800 W
 
|-
 
|-
 
| Bias Power
 
| Bias Power
 
| 0 W
 
| 0 W
| ? W
+
| 20 W
 
|-
 
|-
 
| Bias Pulsing
 
| Bias Pulsing
 
| N/A
 
| N/A
| ?
+
| 100 Hz 80%
 
|-
 
|-
 
| Pressure
 
| Pressure
| ?
+
| 10 mTorr
| ?
+
| 10 mTorr
 
|-
 
|-
 
| C<sub>4</sub>F<sub>8</sub> Flow
 
| C<sub>4</sub>F<sub>8</sub> Flow
| ? sccm
+
| 150 sccm
| 0 sccm
+
| 120 sccm
 
|-
 
|-
 
| SF<sub>6</sub> Flow
 
| SF<sub>6</sub> Flow
 
| 0 sccm
 
| 0 sccm
| ? sccm
+
| 200 sccm
|-
 
| O<sub>2</sub> Flow
 
| 0 sccm
 
| ? sccm
 
 
|-
 
|-
 
| Time
 
| Time
| ? s
+
| 1 s
| ? s
+
| 1.65 s
 +
|-
 +
| Chuck Temperature
 +
|colspan="2" | 20°C
 
|}
 
|}
  
Line 71: Line 70:
 
|-
 
|-
 
| Silicon
 
| Silicon
| ? µm/min
+
| 0.4 µm/min
 
| ?%
 
| ?%
 
|}
 
|}
Line 81: Line 80:
 
! Etch Rate
 
! Etch Rate
 
! Uniformity
 
! Uniformity
 +
|-
 +
| SPR 220
 +
| 110 Å/min
 +
| 8%
 
|-
 
|-
 
| Silicon dioxide
 
| Silicon dioxide
Line 87: Line 90:
 
|-
 
|-
 
| Silicon nitride
 
| Silicon nitride
| ?
+
| 92 Å/min
| ?
+
| 13%
 
|-
 
|-
| SPR 220
+
| Low stress nitride
| 110 Å/min
+
| 80 Å/min
| 8%
+
| 12%
 
|}
 
|}
  
 
===Etch profile===
 
===Etch profile===
Unknown.
+
* Undercut: 80-100 nm
 +
* Sidewall angle: 87-89° (loading dependent)
 +
{{note|This recipe exhibits passivation breakthrough at the top corner of the feature (see image at top of page). This appears to go away for large open areas (isolated lines), but if this will be detrimental to your process, please consider another tool for polysilicon etches.|reminder}}
  
 
==Limitations==
 
==Limitations==
  
 
===Etch length===
 
===Etch length===
This etch is designed for thin films and shallow etches. It is not characterized for long processes.
+
This etch is designed for thin films and shallow etches (< 2 µm). It is not characterized for long processes.
  
 
===Feature size===
 
===Feature size===
Unknown
+
Due to passivation breakthrough at the surface, remaining features narrower than 1 µm will likely be etched away.
  
 
===Open area===
 
===Open area===
 
Unknown
 
Unknown

Latest revision as of 07:46, 19 March 2021

About this Process
STS Pegasus 4 Switched Poly 1 um.jpg
Process Details
Equipment STS Pegasus 4
Technology RIE
Material Silicon
Mask Materials PR, SiO2
Gases Used SF6, C4F8, O2


LNF Switched Poly is a Bosch-style switched process intended for shallow silicon and thin film poly- and amorphous silicon etches.

The STS Pegasus is not designed for polysilicon etching. There are other tools at the LNF specifically designed for this, including the LAM 9400 and the P5000 RIE. Please make a helpdesk ticket if you need assistance determining the correct tool or recipe for your process.

Procedure

Follow the standard operating procedure.

Parameters

Parameter Dep Etch
ICP Power 800 W 800 W
Bias Power 0 W 20 W
Bias Pulsing N/A 100 Hz 80%
Pressure 10 mTorr 10 mTorr
C4F8 Flow 150 sccm 120 sccm
SF6 Flow 0 sccm 200 sccm
Time 1 s 1.65 s
Chuck Temperature 20°C

Capabilities

Etch rate

Etch rate will vary with feature size and loading.

Material Etch Rate Uniformity
Silicon 0.4 µm/min ?%

Mask selectivity

Material Etch Rate Uniformity
SPR 220 110 Å/min 8%
Silicon dioxide 31 Å/min 18%
Silicon nitride 92 Å/min 13%
Low stress nitride 80 Å/min 12%

Etch profile

  • Undercut: 80-100 nm
  • Sidewall angle: 87-89° (loading dependent)
This recipe exhibits passivation breakthrough at the top corner of the feature (see image at top of page). This appears to go away for large open areas (isolated lines), but if this will be detrimental to your process, please consider another tool for polysilicon etches.

Limitations

Etch length

This etch is designed for thin films and shallow etches (< 2 µm). It is not characterized for long processes.

Feature size

Due to passivation breakthrough at the surface, remaining features narrower than 1 µm will likely be etched away.

Open area

Unknown