Difference between revisions of "STS Pegasus 4/Processes/LNF Switched Poly"

From LNF Wiki
Jump to navigation Jump to search
(Created page with "<!-- Make sure to add any other relevant categories --> {{#ifeq: {{NAMESPACE}} | Template | | Category:Processes}} {{warning|This page has not been released yet.}} {{Infob...")
 
Line 27: Line 27:
 
|-
 
|-
 
| ICP Power
 
| ICP Power
| ? W
+
| 800 W
| ? W
+
| 800 W
 
|-
 
|-
 
| Bias Power
 
| Bias Power
 
| 0 W
 
| 0 W
| ? W
+
| 20 W
 
|-
 
|-
 
| Bias Pulsing
 
| Bias Pulsing
 
| N/A
 
| N/A
| ?
+
| 100 Hz 80%
 
|-
 
|-
 
| Pressure
 
| Pressure
| ?
+
| 10 mTorr
| ?
+
| 10 mTorr
 
|-
 
|-
 
| C<sub>4</sub>F<sub>8</sub> Flow
 
| C<sub>4</sub>F<sub>8</sub> Flow
| ? sccm
+
| 150 sccm
| 0 sccm
+
| 120 sccm
 
|-
 
|-
 
| SF<sub>6</sub> Flow
 
| SF<sub>6</sub> Flow
 
| 0 sccm
 
| 0 sccm
| ? sccm
+
| 200 sccm
|-
 
| O<sub>2</sub> Flow
 
| 0 sccm
 
| ? sccm
 
 
|-
 
|-
 
| Time
 
| Time
| ? s
+
| 1 s
| ? s
+
| 1.65 s
 
|}
 
|}
  

Revision as of 13:34, 22 November 2020

Warning Warning: This page has not been released yet.
About this Process
Process Details
Equipment STS Pegasus 4
Technology RIE
Material Silicon
Mask Materials not typical
Chemicals Used PR, SiO2
Gases Used SF6, C4F8, O2


LNF Switched Poly is a Bosch-style switched process intended for shallow silicon and thin film poly- and amorphous silicon etches.

Procedure

Follow the standard operating procedure.

Parameters

Parameter Dep Etch
ICP Power 800 W 800 W
Bias Power 0 W 20 W
Bias Pulsing N/A 100 Hz 80%
Pressure 10 mTorr 10 mTorr
C4F8 Flow 150 sccm 120 sccm
SF6 Flow 0 sccm 200 sccm
Time 1 s 1.65 s

Capabilities

Etch rate

Etch rate will vary with feature size and loading.

Material Etch Rate Uniformity
Silicon ? µm/min ?%

Mask selectivity

Material Etch Rate Uniformity
Silicon dioxide 31 Å/min 18%
Silicon nitride ? ?
SPR 220 110 Å/min 8%

Etch profile

Unknown.

Limitations

Etch length

This etch is designed for thin films and shallow etches. It is not characterized for long processes.

Feature size

Unknown

Open area

Unknown