File list
Jump to navigation
Jump to search
This special page shows all uploaded files.
Date | Name | Thumbnail | Size | Description | Versions |
---|---|---|---|---|---|
16:43, 24 September 2015 | Photoresist without HMDS vapor prime.jpg (file) | ![]() |
195 KB | When photoresist has poor adhesion small features can easily tear off. | 1 |
11:51, 24 September 2015 | Photoresist with HMDS vapor prime.jpg (file) | ![]() |
157 KB | 1 | |
15:37, 25 August 2015 | 200071.jpg (file) | ![]() |
153 KB | 2 | |
12:38, 25 August 2015 | 40061.jpg (file) | ![]() |
192 KB | 2 | |
09:31, 25 August 2015 | 54071.jpg (file) | ![]() |
187 KB | 2 | |
14:52, 18 August 2015 | 53121.jpg (file) | ![]() |
184 KB | 1 | |
14:51, 18 August 2015 | 53111.jpg (file) | ![]() |
191 KB | 2 | |
10:54, 18 August 2015 | 41000.jpg (file) | ![]() |
150 KB | 4 | |
21:06, 17 August 2015 | 150001.jpg (file) | ![]() |
180 KB | 2 | |
10:18, 13 August 2015 | 141031.jpg (file) | ![]() |
163 KB | 1 | |
15:12, 3 August 2015 | CEE Developer recipe name format.png (file) | ![]() |
20 KB | xyz | 1 |
11:38, 3 August 2015 | CEE Incorrect Sample.jpg (file) | ![]() |
45 KB | 3 | |
11:36, 3 August 2015 | CEE Correct Sample.jpg (file) | ![]() |
40 KB | 2 | |
11:04, 3 August 2015 | 53101.jpg (file) | ![]() |
96 KB | 2 | |
16:06, 31 July 2015 | 10061.jpg (file) | ![]() |
95 KB | 2 | |
11:00, 29 July 2015 | 53091.jpg (file) | ![]() |
233 KB | 1 | |
12:23, 26 June 2015 | 140041.jpg (file) | ![]() |
155 KB | 1 | |
12:23, 26 June 2015 | 140020.jpg (file) | ![]() |
151 KB | 1 | |
12:22, 26 June 2015 | 140031.jpg (file) | ![]() |
138 KB | 1 | |
13:25, 10 June 2015 | 10051.jpg (file) | ![]() |
171 KB | 1 | |
09:09, 28 May 2015 | 142001.jpg (file) | ![]() |
276 KB | 1 | |
15:17, 18 May 2015 | 21040.jpg (file) | ![]() |
148 KB | 2 | |
11:33, 4 May 2015 | 53081.jpg (file) | ![]() |
88 KB | 1 | |
10:20, 4 May 2015 | 62040.jpg (file) | ![]() |
150 KB | 2 | |
09:45, 10 March 2015 | 71011.jpg (file) | ![]() |
59 KB | 1 | |
16:21, 29 January 2015 | 10030.jpg (file) | ![]() |
195 KB | 1 | |
14:01, 15 January 2015 | Temp Image.jpg (file) | ![]() |
17 KB | 1 | |
13:55, 15 January 2015 | STS Pegasus 4 Recipe 1 grass.jpg (file) | ![]() |
112 KB | 1 | |
13:20, 15 January 2015 | STS Pegasus 4 Recipe 4 Etch Rate.jpg (file) | ![]() |
43 KB | 1 | |
12:21, 15 January 2015 | STS Pegasus 4 Recipe 4 100 um.jpg (file) | ![]() |
95 KB | 1 | |
12:21, 15 January 2015 | STS Pegasus 4 Recipe 4 10 um.jpg (file) | ![]() |
111 KB | 1 | |
12:20, 15 January 2015 | STS Pegasus 4 Recipe 4 2 um.jpg (file) | ![]() |
113 KB | 1 | |
12:13, 15 January 2015 | STS Pegasus 4 Recipe 3 Etch Rate.jpg (file) | ![]() |
45 KB | 1 | |
12:10, 15 January 2015 | STS Pegasus 4 Recipe 3 100 um.jpg (file) | ![]() |
118 KB | 1 | |
12:10, 15 January 2015 | STS Pegasus 4 Recipe 3 10 um.jpg (file) | ![]() |
125 KB | 1 | |
12:10, 15 January 2015 | STS Pegasus 4 Recipe 3 2 um.jpg (file) | ![]() |
121 KB | 1 | |
11:56, 15 January 2015 | STS Pegasus 4 Recipe 2 Etch Rate.jpg (file) | ![]() |
45 KB | 1 | |
11:41, 15 January 2015 | STS Pegasus 4 Recipe 2 100 um.jpg (file) | ![]() |
114 KB | 1 | |
11:40, 15 January 2015 | STS Pegasus 4 Recipe 2 10 um.jpg (file) | ![]() |
107 KB | 1 | |
11:40, 15 January 2015 | STS Pegasus 4 Recipe 2 2 um.jpg (file) | ![]() |
111 KB | 1 | |
11:07, 15 January 2015 | STS Pegasus 4 Recipe 1 Etch Rate.jpg (file) | ![]() |
42 KB | 1 | |
17:09, 14 January 2015 | STS Pegasus 4 Recipe 1 100 um.jpg (file) | ![]() |
110 KB | 1 | |
17:09, 14 January 2015 | STS Pegasus 4 Recipe 1 10 um.jpg (file) | ![]() |
116 KB | 1 | |
17:03, 14 January 2015 | STS Pegasus 4 Recipe 1 2 um.jpg (file) | ![]() |
112 KB | 1 | |
13:16, 13 January 2015 | Warning.svg (file) | 4 KB | 1 | ||
10:56, 10 December 2014 | 15000.jpg (file) | ![]() |
174 KB | 1 | |
15:09, 24 November 2014 | 10020.jpg (file) | ![]() |
136 KB | 1 | |
16:27, 5 November 2014 | CMP Strasbaugh 6EC.png (file) | ![]() |
316 KB | 1 | |
16:11, 26 September 2014 | LAM 9400.jpg (file) | ![]() |
245 KB | This a picture of the operator interface to the LAM 9400 | 1 |
14:55, 1 May 2014 | CEE Developers.jpg (file) | ![]() |
41 KB | 1 |