Open main menu
Parameter options for {{convert}}
Option =.. Description Note
|abbr=in in Use symbol for first (left-hand side) unit Symbol ('abbreviation')
|abbr=off off Use name for all units Symbol ('abbreviation')
|abbr=none none
|abbr=on on Use symbol for all units Symbol ('abbreviation')
|abbr=out out Use symbol for right-hand side unit (default) Symbol ('abbreviation')
|abbr=values values Show only input and output numbers, not units Parts only
|abbr=~ ~ Shows both unit name and symbol Symbol & name
|adj=j j Join number and unit name using " " instead of a space Join values
|adj=mid|x=... mid User-specified text after the input unit; sets adj=on (adjective) Word adding, adjective
|adj=on on Unit name is adjective (singular and hyphenated) Grammar, adjective
|adj=pre|x=... pre User-specified text before input unit Word adding
|adj=ri0 ri0 Round input with precision 0 Rounding and sigfig
|adj=ri1 ri1 Round input with precision 1 Rounding and sigfig
|adj=ri2 ri2 Round input with precision 2 Rounding and sigfig
|adj=ri3 ri3 Round input with precision 3 Rounding and sigfig
|disp=b b Join input and output using " (...)" (default) Join values
|disp=sqbr sqbr Join input and output using " [...]" Join values
|disp=br br Join input and output using "<br/>" Join values
|disp=comma comma Join input and output using ", " Join values
|disp=or or Join input and output using " or " Join values
|disp=number number Display output number only Parts only
|disp=output number only output number only
|disp=out out Display only output number and name/symbol Parts only
|disp=output only output only
|disp=preunit|x=... preunit User-specified text before input and output units Word adding
|disp=table table Output is suitable for a table cell with align="right" Table columns
|disp=tablecen tablecen Output is suitable for a table cell with align="center" Table columns
|disp=unit unit Display input name/symbol only ( not input number, not output) Parts only
|disp=unit2 unit2 Display output name/symbol only (not input; not output number) Parts only
|disp=x|... x Join input and output using user-specified text Word adding
|comma=5 05 Only use comma for thousands separator if 5 or more digits Number format
|comma=gaps gaps Use gaps (space), not comma, for thousands separator Number format
|comma=gaps5 gaps5 Use gaps (space), but only if 5 or more digits Number format
|comma=off off No thousands separator Number format
|frac=N N Show imperial number in fractions, denominator=N Number format, fraction
|lk=in in Link left-hand side unit name or symbol Unit link
|lk=on on Link all unit names or symbols (but not twice for the same unit) Unit link
|lk=out out Link right-hand side unit name or symbol Unit link
|order=flip flip Inverts order of input, output measurements (conversion first) Order
|round=5 05 Rounds calculation to the nearest multiple of 5 Rounding and sigfig
|round=25 25 Rounds calculation to the nearest multiple of 25 Rounding and sigfig
|round=each each In a range, each number is rounded by the default rounding Rounding and sigfig
|sigfig=N N Round output number to N significant figures (N is a positive integer) Rounding and sigfig
|sortable=in in Output numeric hidden sort field for use in a sortable table (based on input) Table sort
|sortable=on on
|sortable=out out Output numeric hidden sort field for use in a sortable table (based on output) Table sort
|sp=us us Use U.S. spelling (like "meter" instead of default "metre") Spelling U.S. names
|spell=in in Spell input number in words Spelling numbers
|spell=In In Spell input number in words with first letter uppercase Spelling numbers
|spell=on on Spell input and output numbers in words Spelling numbers
|spell=On On Spell input and output numbers in words with first letter uppercase Spelling numbers
|$= $ Replace $-sign with a currency sign, for example in $/acre (no currency conversion happens) Cost per unit
|debug=yes yes Debugging only. In a sortable table: show the normally hidden sort key Table sort
|abbr=comma comma Deprecated. Use |comma=off Number format
|abbr=mos mos Deprecated. Use |x| or |by| Range format
|adj=1 01 Deprecated. Do not use. No need to deviate from MOS regarding plurals Plural or singular
|adj=flip flip Deprecated. Use |order=flip Order
|adj=nocomma nocomma Deprecated. Use |comma=off Number format
|disp=2 02 Deprecated. Use |disp=output only Parts only
|disp=5 05 Deprecated. Use |round=5 Rounding and sigfig
|disp=flip flip Deprecated. Use |order=flip Order
|disp=flip5 flip5 Deprecated. Use |order=flip |round=5 Order, rounding
|disp=nocomma nocomma Deprecated. Use |comma=off Number format
|disp=u2 u2 Deprecated. Use |disp=unit2 Parts only
|near=5 05 Deprecated. Use |round=5 Rounding and sigfig
Template documentation[create]