Tempress S3T3 - Flat Poly-Si 4"
The Tempress diffusion system is a modular horizontal furnace designed to process silicon wafers as part of the manufacturing technology of semiconductor, optical, MEMS, and solar devices. Polysilicon, Low Stress Poly-Si, and Amorphous silicon are formed by using a process called LPCVD, Low Pressure Chemical Vapor Deposition. Chemical vapor deposition forms thin films on the surface of a substrate by thermal decomposition and/or reaction of gaseous compounds. The desired material is deposited directly from the gas phase onto the surface of the wafer. The important factors are gas ratio, temperature, and pressure.
| Tempress S3T3 - Flat Poly-Si 4" | |
|---|---|
| Equipment Details | |
| Technology | LPCVD |
| Materials Restriction | CMOS Clean |
| Sample Size | 100mm |
| Gases Used | N2, SiH4 |
| Equipment Manual | |
| Overview | System Overview |
| Operating Procedure | SOP |
| Supported Processes | Polysilicon, Annealed polysilicon, Amorphous silicon |
| Maintenance | Maintenance |
Contents
Announcements
- No announcements at this time.
Capabilities
- Polysilicon
- Annealed polysilicon
- Amorphous silicon
- Maximum Thickness
- Polysilicon - 2µm
- Annealed Polysilicon - 10µm
- Amorphous Silicon - 2µm
System overview
Hardware details
Substrate requirements
- Silicon only
- Can process up to 25, 100 mm (4") wafers
- Wafer thickness, ~525um for 100mm (4")
Material restrictions
The Tempress S3T3 - Flat Poly-Si 4" is designated as a CMOS Clean class tool. Below is a list of approved materials for the tool. Approved means the material is allowed in the tool under normal circumstances. If a material is not listed, please create a helpdesk ticket or email info@lnf.umich.edu for any material requests or questions.
Supported processes
Process details
Characterization data
Standard operating procedure
Checkout procedure
- Create a Helpdesk Ticket requesting training.
- A process engineer will schedule a time for initial training. After completing training the user can attempt a checkout session. It may be necessary for some users to participate in more than one training session, prior to attempting check out.
- Schedule a checkout session with a tool engineer via the Helpdesk Ticket system. If this checkout is successful, the engineer will authorize you on the tool.
Maintenance
- Boats and dummy wafers are replaced every 20-30µm of accumulated deposition.
- Tube is replaced at 100µm of accumulated deposition.