Tempress S3T3 - Flat Poly-Si 4"

From LNF Wiki
Revision as of 13:29, 7 September 2023 by Terreb (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search



Tempress S3T3 - Flat Poly-Si 4"
30111.jpg
Equipment Details
Technology LPCVD
Materials Restriction CMOS Clean
Sample Size 100mm
Gases Used N2, SiH4
Equipment Manual
Overview System Overview
Operating Procedure SOP
Supported Processes Polysilicon, Annealed polysilicon, Amorphous silicon
Maintenance Maintenance

The Tempress diffusion system is a modular horizontal furnace designed to process silicon wafers as part of the manufacturing technology of semiconductor, optical, MEMS, and solar devices. Polysilicon, Low Stress Poly-Si, and Amorphous silicon are formed by using a process called LPCVD, Low Pressure Chemical Vapor Deposition. Chemical vapor deposition forms thin films on the surface of a substrate by thermal decomposition and/or reaction of gaseous compounds. The desired material is deposited directly from the gas phase onto the surface of the wafer. The important factors are gas ratio, temperature, and pressure.

Announcements

  • No announcements at this time.

Capabilities

System overview

Hardware details

  • N2 - Maximum flow 10 slpm
  • SiH4 - Maximum flow 300 sccm

Substrate requirements

  • Silicon only
  • Can process up to 25, 100 mm (4") wafers
  • Wafer thickness, ~525um for 100mm (4")
All samples must go through the RCA Pre-Furnace clean procedure before being processed in the furnace

Material restrictions

The Tempress S3T3 - Flat Poly-Si 4" is designated as a CMOS Clean class tool. Below is a list of approved materials for the tool. Approved means the material is allowed in the tool under normal circumstances. If a material is not listed, please create a helpdesk ticket or email info@lnf.umich.edu for any material requests or questions.


Supported processes

Process details

Characterization data

Standard operating procedure

Checkout procedure

  1. Create a Helpdesk Ticket requesting training.
  2. A process engineer will schedule a time for initial training. After completing training the user can attempt a checkout session. It may be necessary for some users to participate in more than one training session, prior to attempting check out.
  3. Schedule a checkout session with a tool engineer via the Helpdesk Ticket system. If this checkout is successful, the engineer will authorize you on the tool.

Maintenance

  • Boats and dummy wafers are replaced every 20-30µm of accumulated deposition.
  • Tube is replaced at 100µm of accumulated deposition.